Replacing a Hesai XT32

Eight checks that decide whether an ERDI LRF1829C can stand in for a Hesai XT32 in your build. Every ERDI figure below is published and dated; every Hesai figure has to come from Hesai's own documentation.

What this page does not do: it does not restate Hesai's specification for the XT32. We do not republish another manufacturer's numbers. Open their site — https://www.hesaitech.com/ and fill the right-hand column of your own copy of this checklist.

The eight checks

CheckWhat ERDI publishes for the LRF1829C
Working range and target reflectivity
Range quoted against a white board is not the range at 10% reflectivity. Confirm the vendor figure's target, then derate for your own target.
Published range and its stated test condition are on the model page; the reflectivity caveat is printed next to it.
Interface and protocol
Same connector does not mean same protocol. UART framing, baud rate and command set differ between vendors and often between models of one vendor.
Protocol family, default baud rate and frame format are documented in /docs/protocols/ with a working decoder.
Supply voltage and current
A 5 V module and a 9–36 V module are not drop-in equivalents; peak current on the first pulse is usually the part that browns out a shared rail.
Supply range, standby / average / peak current are published per model.
Update rate versus host loop
A 1 kHz module on a 50 Hz control loop buys nothing. Match the rate to what the host can actually consume without dropping frames.
Update rate and the recommended host-side read pattern are documented per model.
Mechanical envelope and mounting
Window position, optical axis height and mounting holes decide whether the swap is a bracket change or an enclosure redesign.
Dimensions, weight and the optical reference point are published with the mechanical drawing.
Environmental and ingress
IP rating is a claim about the assembled unit, not the bare module. Condensation and window contamination dominate field failures.
Operating temperature and the ingress statement are published per model; final rating depends on your enclosure.
Eye safety and the complete configuration
The module's class statement is not the class of your finished product. Collimation, window and pulsing change accessible emission.
The laser-safety statement for each module is published and explicitly scoped to the module.
Second-source and lifecycle
The real cost of a swap shows up at the second order. Check lifecycle status before designing in a part that is already end-of-life.
Lifecycle status and the current published price are on the model page; we do not quote what we cannot hold.

ERDI LRF1829C — the figures you would be designing against

ParameterPublished value
Measurement range≤50 m
Accuracy±2 m
Communication interfaceRS422
Supply voltageDC12 V
Published priceFrom $3,500 USD / unit

Full LRF1829C specification and datasheet →

How to use this list

Copy the table into your own review. For each row, write the Hesai XT32 value from the vendor document beside the ERDI value. A substitution is only safe where every row you care about is either equal, better, or has an accepted workaround written next to it. Rows you cannot fill are not "probably fine" — they are open risks.

Questions

Can I drop in an ERDI LRF1829C in place of a Hesai XT32?

Only after the eight checks below are satisfied for your own target, host and enclosure. We do not claim pin, protocol or mechanical equivalence with any third-party model.

Do you publish Hesai XT32 specifications?

No. We do not republish another manufacturer's specification sheet. Use their own documentation as the reference, and treat the checks below as the list of figures you need from it.

What is published for the ERDI module instead?

Range with its test condition, accuracy, interface, supply, dimensions, weight and the module laser-safety statement, all on the model page and dated.

Send your requirement Datasheet and price