Independent evaluation guide — not an official LightWare document. Keyword pairing does not establish equivalence. Source completeness does not establish compatibility or a current commercial offer.
Reading the datasheet
For a LightWare SF30/D datasheet review, start with an original manufacturer document that identifies the exact part and hardware revision. A reseller listing or search excerpt is not a substitute for a complete technical manual. Keep the document revision, retrieval date and relevant page together so that a later engineering review can reproduce the comparison rather than rely on an undated summary.
Read measurement range alongside the target reflectivity, ambient light, target size and measurement mode used to obtain it. Accuracy, repeatability and output resolution describe different properties and should not be interchanged. Check whether an advertised maximum refers to a particular target or operating condition before putting it into a system requirement. Missing test conditions remain an open question, not a favorable assumption.
The supplied keyword list pairs this term with ERDI LRF1500H for evaluation only. Request the applicable ERDI document and compare the same fields under comparable conditions. Record the interface revision, connector drawing, mechanical reference and environmental limits before selecting a prototype. The table below is deliberately evidence-gated: an empty source record produces a visible verification gap instead of a guessed specification.
Source-gated comparison
Competitor values use the supplied source URL, capture date and confidence record; ERDI values additionally require a matching source excerpt. Capture dates record retrieval, not publication or revision dates. Missing or unsupported entries stay marked as Not published, describing a gap in the supplied evidence rather than an exhaustive vendor search.
LightWare SF30/D | ERDI LRF1500H | parameter verification
Parameter
LightWare SF30/D
ERDI LRF1500H
Measurement range (m)
0.2-200
0.05-1500 m (90% reflectivity); 0.05-300 m (10% reflectivity)
0.05-1500 m (90% reflectivity); 0.05-300 m (10% reflectivity) | ±10 cm (<10 m); 1% (≥10 m) | UART/IIC | 9-36 V DC | 33 × 34 × 18 mm
Frequently asked questions
Where should I obtain the SF30/D datasheet?
Use the original manufacturer document for the exact hardware revision. A source URL and capture date are recorded only when the relevant content has actually been reviewed; this page is not the manufacturer manual.
Why are some SF30/D comparison cells marked Not published?
The supplied parameter record lacks a usable value or complete source metadata. ERDI entries additionally require a supporting source excerpt. These are evidence gaps in this record, not zero values and not proof that the feature is absent.
How do I ask ERDI about LRF1500H?
Use the model link to review the candidate, then send the intended application, target conditions, host interface and quantity through the contact page. Request the applicable documents and a scoped assessment rather than assuming compatibility.
Discuss the ERDI candidate
Provide the required measurement function and operating conditions so the candidate can be assessed against the application. Model names and this planning association alone do not constitute a compatibility recommendation.