Is ERDI LRF1500H a drop-in replacement for SF40?
No drop-in claim is made. Mechanical, electrical, protocol and system behavior require separate review and acceptance testing for the actual application.
Independent evaluation guide — not an official LightWare document. Keyword pairing does not establish equivalence. Source completeness does not establish compatibility or a current commercial offer.
A LightWare SF40 replacement project should begin with a record of the installed component, hardware revision, cable assembly and host software behavior. Determine whether the change is driven by availability, packaging, performance or maintenance before choosing a candidate. ERDI LRF1500H appears in the supplied keyword mapping as a discussion candidate only; this page does not claim drop-in compatibility or an approved substitution.
Review mechanical, electrical and software changes as separate work items. Compare mounting features, optical clearance, connector orientation, power requirements and data handling against source documents. Preserve the original configuration and define how to reverse the change if the prototype fails acceptance. A successful distance reading on a workbench does not establish correct operation across the full environment or every host-system error condition.
Agree on a staged validation plan covering startup, normal measurement, invalid results, reconnection and representative field conditions. Retain logs and document any adapter, firmware or calibration changes introduced during the trial. Ask ERDI to review the intended application and the evidence gaps for LRF1500H before ordering a production quantity. Approve the substitution only after the responsible system owner has reviewed the test results.
Competitor values use the supplied source URL, capture date and confidence record; ERDI values additionally require a matching source excerpt. Capture dates record retrieval, not publication or revision dates. Missing or unsupported entries stay marked as Not published, describing a gap in the supplied evidence rather than an exhaustive vendor search.
| Parameter | LightWare SF40 | ERDI LRF1500H |
|---|---|---|
| Measurement range (m) | 0.2-100 | 0.05-1500 m (90% reflectivity); 0.05-300 m (10% reflectivity) |
| Accuracy (cm) | Not published | ±10 cm (<10 m); 1% (≥10 m) |
| Update rate (Hz) | 5.5 | Not published |
| Electrical interface and protocol | UART | UART/IIC |
| Supply voltage (V) | 12 (motor) / 5 (laser) | 9-36 V DC |
| Wavelength (nm) | 905 | Not published |
| Field of view (deg) | 360 | Not published |
| Published price (USD) | 399.0 | Not published |
Source: https://lightwarelidar.com/wp-content/uploads/2025/10/SF40-Laser-Scanner-Manual-Rev-7.pdf (captured , confidence high)
SOURCE_URL: https://erdilrf.com/models/lrf1500h/
CAPTURED_AT:
0.05-1500 m (90% reflectivity); 0.05-300 m (10% reflectivity) | ±10 cm (<10 m); 1% (≥10 m) | UART/IIC | 9-36 V DC | 33 × 34 × 18 mm
No drop-in claim is made. Mechanical, electrical, protocol and system behavior require separate review and acceptance testing for the actual application.
The supplied parameter record lacks a usable value or complete source metadata. ERDI entries additionally require a supporting source excerpt. These are evidence gaps in this record, not zero values and not proof that the feature is absent.
Use the model link to review the candidate, then send the intended application, target conditions, host interface and quantity through the contact page. Request the applicable documents and a scoped assessment rather than assuming compatibility.
Provide the required measurement function and operating conditions so the candidate can be assessed against the application. Model names and this planning association alone do not constitute a compatibility recommendation.