When one host talks to several rangefinder modules on the same UART - or to one module through a radio link with latency - the hard problem is no longer parsing a frame. It is knowing which measurement a frame belongs to.

This note describes a simple, robust scheme that works with any module whose protocol carries an address or a command echo, and what to do when it does not.

The failure mode​

A host sends MEASURE to sensor A. The reply arrives late; meanwhile the host sends MEASURE to sensor B. If the parser accepts "the next frame that looks valid", B's reply can be attributed to A. The distance is real, the timestamp is wrong, and nothing in the log looks broken.

At 10 Hz this is rare. At 1 kHz, or over a half-duplex RS-485 link with arbitration, it is routine.

Three association rules, in order of preference​

  1. Address in the frame. If the protocol carries a source address (or the reply echoes the command), key pending requests by (address, command, sequence). Reject replies whose key is not pending.
  2. Explicit sequence number. Some protocols number requests. Increment per request, wrap at the field width, and never reuse a number while the reply window is open.
  3. Timing window with one outstanding request. If the protocol gives no identifier, keep exactly one request in flight. The next frame received inside the timeout belongs to that request; anything outside the window is discarded. This costs throughput but removes ambiguity.

Never mix rule 3 with "just read whatever arrives" - that is the case that produces silently misattributed data.

Timing budget​

For each request, record:

t_send host wrote the last byte
t_first first byte of the reply
t_last last byte of the reply

The deadline is t_send + (frame_time × 2) + processing_margin. Frame time is bytes × 10 / baud. At 115200 baud, an 8-byte frame takes about 0.7 ms; at 9600 baud, about 8.3 ms. A 20 Hz module on a 9600-baud link can saturate the wire with replies alone - check the arithmetic before blaming the sensor.

What to expose to the control loop​

  • Measurement timestamp, taken at t_first or t_last and carried with the value. A distance without a timestamp is not a measurement.
  • Request id or sequence so the value can be traced back in the log.
  • Validity flag that distinguishes "no reply", "checksum error", "out-of-range reply" and "valid distance". These are different faults with different fixes.

A parser sketch​

pending = {} # key -> (sent_at, deadline)
def request(addr, cmd):
key = (addr, cmd, next_seq())
pending[key] = now() + timeout
write_frame(addr, cmd)
return key

def on_frame(frame):
key = frame.key() # address/seq from the frame
if key not in pending: # late, duplicate or unsolicited
return "unmatched"
del pending[key]
return parse(frame)

Expire entries in pending on every loop tick, and count expiries. A rising expiry count is the earliest signal that the bus is losing frames - earlier than a wrong distance will show it.