Benewake TFmini Plus datasheet guide

Independent evaluation guide — not an official Benewake document. Keyword pairing does not establish equivalence. Source completeness does not establish compatibility or a current commercial offer.

Reading the datasheet

For a Benewake TFmini Plus datasheet review, start with an original manufacturer document that identifies the exact part and hardware revision. A reseller listing or search excerpt is not a substitute for a complete technical manual. Keep the document revision, retrieval date and relevant page together so that a later engineering review can reproduce the comparison rather than rely on an undated summary.

Read measurement range alongside the target reflectivity, ambient light, target size and measurement mode used to obtain it. Accuracy, repeatability and output resolution describe different properties and should not be interchanged. Check whether an advertised maximum refers to a particular target or operating condition before putting it into a system requirement. Missing test conditions remain an open question, not a favorable assumption.

The supplied keyword list pairs this term with ERDI LRF100H for evaluation only. Request the applicable ERDI document and compare the same fields under comparable conditions. Record the interface revision, connector drawing, mechanical reference and environmental limits before selecting a prototype. The table below is deliberately evidence-gated: an empty source record produces a visible verification gap instead of a guessed specification.

Source-gated comparison

Competitor values use the supplied source URL, capture date and confidence record; ERDI values additionally require a matching source excerpt. Capture dates record retrieval, not publication or revision dates. Missing or unsupported entries stay marked as Not published, describing a gap in the supplied evidence rather than an exhaustive vendor search.

Benewake TFmini Plus | ERDI LRF100H | parameter verification
ParameterBenewake TFmini PlusERDI LRF100H
Measurement range (m)0.1-120.05-100 m (90% reflectivity); 0.05-30 m (10% reflectivity)
Accuracy (cm)5±10 cm (<10 m); 1% (≥10 m)
Update rate (Hz)1-1000Not published
Electrical interface and protocolUART/I2C/I/OUART, IIC
Supply voltage (V)Not published9-36 V DC
Wavelength (nm)Not publishedNot published
Field of view (deg)3.6Not published
Published price (USD)Not publishedNot published

Evidence and limitations

Benewake TFmini Plus source record

Source: https://en.benewake.com/TFminiPlus/index.html (captured , confidence medium)

ERDI LRF100H source record

SOURCE_URL: https://erdilrf.com/models/lrf100h/
CAPTURED_AT:

0.05-100 m (90% reflectivity); 0.05-30 m (10% reflectivity) | ±10 cm (<10 m); 1% (≥10 m) | UART, IIC | 9-36 V DC | 33 × 34 × 18 mm

Frequently asked questions

Where should I obtain the TFmini Plus datasheet?

Use the original manufacturer document for the exact hardware revision. A source URL and capture date are recorded only when the relevant content has actually been reviewed; this page is not the manufacturer manual.

Why are some TFmini Plus comparison cells marked Not published?

The supplied parameter record lacks a usable value or complete source metadata. ERDI entries additionally require a supporting source excerpt. These are evidence gaps in this record, not zero values and not proof that the feature is absent.

How do I ask ERDI about LRF100H?

Use the model link to review the candidate, then send the intended application, target conditions, host interface and quantity through the contact page. Request the applicable documents and a scoped assessment rather than assuming compatibility.

Discuss the ERDI candidate

Provide the required measurement function and operating conditions so the candidate can be assessed against the application. Model names and this planning association alone do not constitute a compatibility recommendation.