Skip to main content
Explore ERDILRF
ERDILRF LaserOptics. Electronics. Integration.
Products
905 nm sensors & rangefindersLR seriesSPD seriesH seriesVB seriesLRF A seriesOther product platforms1.54 µm laser sources1535 nm rangefindersAll products
Applications
Application overviewOptical observationCivil UAVsSite monitoringIndustrial sensingHandheld instrumentsField measurement
Insights
Product SpotlightEngineering knowledgeProduct filmsInside ERDILRF
Support
Technical supportFrequently asked questionsModel selectorContact our team
Downloads
All downloadsDrivers & integrationDeveloper docsEngineering community (Q&A)Specifications & CAD
How to buy
Samples & quotationsPrice listCompare modulesDealer programRequest a sample
Company
About ERDILRFCertificatesContact usPrivacy policyTerms
Talk to Sales

Press ↑↓ to move, Enter to open, Esc to close.

Published range
0.05–100 m (90% reflectivity); 0.05–30 m (10% reflectivity)The two source values remain bound to their stated target reflectivity.
Interface
UART, IIC
Wavelength
905 nm
Weight
20 ± 2 g

The details

LRF100H specifications

Read every value with its conditions. View the model documents for integration.

Basic ranging performance

LRF100H Basic ranging performance
ParameterSpecification & conditions
Measurement range0.05–100 m (90% reflectivity); 0.05–30 m (10% reflectivity)The two source values remain bound to their stated target reflectivity.
Measurement frequency20 Hz-10 kHz (default: 1 kHz)
Accuracy±10 cm (<10 m); 1% (≥10 m)
Repeatability±5 cm (<10 m); ±10 cm at 100 m
Ambient-light immunity100 klx
Reported resolution1 cmFront-page feature statement; not an accuracy value

Optical parameters

LRF100H Optical parameters
ParameterSpecification & conditions
Central wavelength905 nm
Photobiological safetyClass 1
Field of viewAbout 4 mrad
Wavelength for indicationN/A
Photobiological safety for indicationN/A

Electrical and communication interface

LRF100H Electrical and communication interface
ParameterSpecification & conditions
Supply voltage9–36 V DC
Peak current100 mA
Average current30 mA
Average power consumption0.7 W
Communication interfaceUART, IIC

Mechanical and environmental

LRF100H Mechanical and environmental
ParameterSpecification & conditions
Protection levelN/A
Dimensions33 × 34 × 18 mm
Weight20 ± 2 g
Operating temperature−20 °C to +60 °C
Wire specification1.25 mm, 5P, 50 cm stranded wires
CustomizationAvailable in appearance / structure / output protocol

Documents

Document notes & versions
ENGINEERING FILES

Technical Downloads

Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.

Product overview

LRF100H 905 nm LiDAR Distance Sensor

LRF100H is a laser rangefinder module for industrial sensing, with a published test range of 100 m and a UART interface. Confirm target conditions, configuration and the current datasheet before integration.

LRF100H is a 33 × 34 × 18 mm, 20 g industrial DToF sensor (905 nm) covering 0.05–100 m with 20 Hz–10 kHz output, for wind-power, landslide and level monitoring on 9–36 V.

WhatsApp about LRF100H
From $80 USD / unitLowest published unit price at 1000+ pieces. Shipping included.
B2B PURCHASING

Volume Pricing

Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.

USD / unit
1–19 piecesBase tier$200 USDPublished unit price
20–30 pieces$190 USDSave 5%
31–500 pieces$140 USDSave 30%
501–999 pieces$120 USDSave 40%
1000+ piecesLowest unit price$80 USDLowest published price · Save 60%
Commercial terms and lead time are confirmed in the quotation.

Integration library

Go into the details.

Drawings, test conditions and application notes. Open the part you need.

Selection
SELECTION

Choosing LRF100H against nearby models

Range is 0.05–100 m at 90% and 0.05–30 m at 10%. LRF200H shares the housing and doubles range; LRF50H is the smaller 50 m unit.

Accuracy ±10 cm below 10 m, 1% beyond.

Published unit prices start at $80 at 1000+ pieces; see Volume Pricing for all quantity bands.

Technical documentation & drawings
SPECIFICATIONS

LRF100H datasheet values

Figures are reproduced from the LRF100H datasheet. Read each value together with the test condition printed beside it.

Ranging

ParameterValueSource condition
Measurement range0.05-100 m (90% reflectivity); 0.05-30 m (10% reflectivity)Range differs with target reflectivity.
Measurement frequency20 Hz-10 kHz (default: 1 kHz)Per model datasheet
Accuracy±10 cm (<10 m); 1% (≥10 m)Per model datasheet
Repeatability±5 cm (<10 m); ±10 cm at 100 mPer model datasheet
Ambient-light immunity100 klxPer model datasheet
Reported resolution1 cmFeature claim, not a measured accuracy

Optics

ParameterValueSource condition
Central wavelength905 nmPer model datasheet
Photobiological safetyClass 1Per model datasheet
Field of viewAbout 4 mradPer model datasheet
Wavelength for indicationN/APer model datasheet
Photobiological safety for indicationN/APer model datasheet

Power and data interface

ParameterValueSource condition
Supply voltage9-36 V DCPer model datasheet
Peak current100 mAPer model datasheet
Average current30 mAPer model datasheet
Average power consumption0.7 WPer model datasheet
Communication interfaceUART, IICPer model datasheet

Mechanics and environment

ParameterValueSource condition
Protection levelN/APer model datasheet
Dimensions33 × 34 × 18 mmPer model datasheet
Weight20 ± 2 gPer model datasheet
Operating temperature-20°C to +60°CPer model datasheet
Wire specification1.25 mm, 5P, 50 cm stranded wiresPer model datasheet
CustomizationHousing, structure and output protocol can be customisedPer model datasheet

Pin assignment

Signal names and directions are transcribed from the model source.

PinSignalFunction
19-36V (red)External power positive
2Power GND (black)External power negative
3Port GND (yellow)GND
4TX (green)Host RX
5RX (blue)Host TX

Drawings

These figures are extracted from the named model source without generative modification.

LRF100H five-pin electrical interface definition
Electrical interface definitionFive-pin 9-36 V power, ground and UART TX/RX definition extracted from page 3; no unstated IIC pin mapping is added.
LRF100H two-dimensional mechanical drawing
Mechanical dimension drawingTwo-dimensional 33 × 34 × 18 mm source drawing extracted from page 3.
Integration checklist
INTEGRATION

Integrating LRF100H into your design

  • Supply: 9–36 V DC, 0.7 W.
  • UART and IIC.
  • Rate: 20 Hz–10 kHz, default 1 kHz.
  • Operating temperature −20 °C to +60 °C.
Applications
APPLICATIONS

Where LRF100H is used

  • Wind-turbine monitoring. Blade or tower clearance distance.
  • Slope and landslide monitoring. Distance changes on unstable ground.
  • Level measurement. Silos and reservoirs.
Questions & answers
FAQ

LRF100H integration questions

How far on dark surfaces?

About 30 m at 10% reflectivity.

UART or IIC?

Both are listed.

What is the default rate?

1 kHz.

HARDWARE

LRF100H mounting, wiring and commands

Taken from the LRF100H outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.

Mounting

Four M2 threaded holes on the lens face, 5 mm thread depth, on a 29 x 13.25 mm pattern. Use M2 screws that engage no more than 5 mm.

Request the LRF100H STEP model for your bracket design.

Pin definition

PinSignalWireConnection
19-36 Vredexternal power +
2Power GNDblackexternal power -
3Port GNDyellowsignal ground
4TXgreenconnect to host RX
5RXblueconnect to host TX

Serial settings

Default baud rate
460800 bit/s
Frame format
8N1
Checksum
Command frames: add bytes 2 to the second-last byte, invert the result (bitwise NOT) and keep the low 8 bits.

Common commands

CommandSend (hex)Reply (hex)Notes
Read serial number5A 0D 02 0D 0D D65A 8D 02 10 01 5FReply 10 01 = serial number 272 (little-endian).
Read firmware version5A 16 02 16 16 BB5A 96 02 03 02 62Reply 03 02 = V2.3.
Set baud rate to 1152005A 06 02 80 04 735A 86 02 80 04 F3Little-endian codes: 60 00 = 9600, C0 00 = 19200, 80 01 = 38400, 80 04 = 115200, 00 09 = 230400, 00 0A = 256000, 00 12 = 460800.
Set output frequency to 1000 Hz5A 0B 02 E7 03 085A 8B 02 E7 03 88E7 03 = divisor 999; f = 1,000,000 / (divisor + 1).

Frames follow the LRF100H user manual; every full frame has been checked against the manual's checksum rule. Open-source drivers: Drivers & wiring.

Engineering Q&A

Questions about LRF100H

Answered by ERDI engineers in the community.

Ask an engineer about LRF100H

LRF100H quick answers

What are the LRF100H dimensions?
33 × 34 × 18 mm.
How much does the LRF100H weigh?
20 ± 2 g.
What power does the LRF100H need?
Supply: 9–36 V DC.
Which interface does the LRF100H use?
UART, IIC.
How much does one LRF100H cost?
$200 for 1 piece, shipping included. Volume price from $80 at 1,000+ pieces.
What is the minimum order for the LRF100H?
1 piece. Pay online by card or PayPal, or by bank transfer; shipping is free worldwide.
What is the LRF100H lead time?
Standard warranty: one year. The lead time is stated on your proforma invoice (PI) before you pay.

Laser safety & status

Laser class
Class 1 (IEC 60825-1)
Status
Available to order

Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.

ERDI TECH

Manufacturer · Chengdu · Founded 2021

Evidence-backed certifications: ISO 9001 · CE EMC

Technical inquiry

Discuss LRF100H for your application.

Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.

Request a review or quotation

Start with your work email and one line about the module or application. Add technical details if you have them.

No models attached.Name the models you are comparing in the requirement, or send the requirement without one.
Send me
Add technical requirements (optional)
Add project & contact details (optional)
Preparing the form. You can also send your request by email.

We reply within one business day (Chengdu, UTC+8).