Independent evaluation guide — not an official Benewake document. Keyword pairing does not establish equivalence. Source completeness does not establish compatibility or a current commercial offer.

Qualifying an alternative

When investigating a Benewake TFmini-S alternative, write down the function the existing device performs before comparing model names. A distance reading, a scan, a point cloud and a handheld measurement workflow are not interchangeable deliverables. The keyword mapping to ERDI LRF100H is a starting point for discussion only. It does not establish equivalent sensing architecture, coverage, software support or performance.

Build a requirement matrix covering target type, working distance, update behavior, measurement uncertainty, ambient conditions and physical space. Then check power, electrical signal levels, host protocol and required accessories against original documents. A candidate that meets one headline distance figure may still fail the application because its coverage, timing, mounting or communication behavior is different. Document both matched requirements and unresolved questions.

Before committing to a change, agree on a representative bench test and a field test with explicit acceptance criteria. Include difficult surfaces, expected lighting, vibration, startup behavior and loss-of-signal handling where relevant to the application. Ask ERDI to assess the proposed use case against the delivered revision of LRF100H. Keep the original component available until the alternative has passed the agreed system-level checks.

Source-gated comparison

Competitor values use the supplied source URL, capture date and confidence record; ERDI values additionally require a matching source excerpt. Capture dates record retrieval, not publication or revision dates. Missing or unsupported entries stay marked as Not published, describing a gap in the supplied evidence rather than an exhaustive vendor search.

Benewake TFmini-S | ERDI LRF100H | parameter verification
ParameterBenewake TFmini-SERDI LRF100H
Measurement range (m)0.1-120.05-100 m (90% reflectivity); 0.05-30 m (10% reflectivity)
Accuracy (cm)6±10 cm (<10 m); 1% (≥10 m)
Update rate (Hz)1-1000Not published
Electrical interface and protocolUART/I2C/I/OUART, IIC
Supply voltage (V)Not published9-36 V DC
Wavelength (nm)Not publishedNot published
Field of view (deg)Not publishedNot published
Published price (USD)Not publishedNot published

Evidence and limitations

Benewake TFmini-S source record

Source: https://en.benewake.com/TFminiS/index.html (captured , confidence medium)

ERDI LRF100H source record

SOURCE_URL: https://erdilrf.com/models/lrf100h/
CAPTURED_AT:

0.05-100 m (90% reflectivity); 0.05-30 m (10% reflectivity) | ±10 cm (<10 m); 1% (≥10 m) | UART, IIC | 9-36 V DC | 33 × 34 × 18 mm

Frequently asked questions

How should I qualify an alternative to TFmini-S?

Define the required measurement function first, then compare documented performance, integration requirements and test results. A keyword match is not proof of equivalent architecture or suitability.

Why are some TFmini-S comparison cells marked Not published?

The supplied parameter record lacks a usable value or complete source metadata. ERDI entries additionally require a supporting source excerpt. These are evidence gaps in this record, not zero values and not proof that the feature is absent.

How do I ask ERDI about LRF100H?

Use the model link to review the candidate, then send the intended application, target conditions, host interface and quantity through the contact page. Request the applicable documents and a scoped assessment rather than assuming compatibility.