Dimetix DPE-30-500 comparison guide

Independent evaluation guide — not an official Dimetix document. Keyword pairing does not establish equivalence. Source completeness does not establish compatibility or a current commercial offer.

Comparing like-for-like evidence

This Dimetix DPE-30-500 comparison with ERDI LRF0305C is an evaluation worksheet, not a declaration that the devices are equivalent. Begin by checking what each device actually outputs and what the host system needs. Different sensing architectures can serve different tasks even when their product descriptions share distance-related vocabulary. The supplied keyword association alone is not evidence of comparable coverage or suitability.

Use original source documents for both columns and keep every value attached to its test conditions. Compare range against the same target assumptions, accuracy against the same distance interval and update behavior against the same operating mode. Do not substitute a peak value for a sustained value or silently mix data from different revisions. Where the evidence is missing, the honest result is an unresolved field.

Review the complete integration boundary: electrical levels, connector orientation, protocol framing, mounting datum, operating environment and error reporting. Assign a test to every requirement that documents alone cannot settle. A final selection should follow a recorded engineering review and a representative prototype evaluation, not a count of favorable cells in a table. Contact ERDI with the worksheet to establish which candidate configuration should be assessed.

Source-gated comparison

Competitor values use the supplied source URL, capture date and confidence record; ERDI values additionally require a matching source excerpt. Capture dates record retrieval, not publication or revision dates. Missing or unsupported entries stay marked as Not published, describing a gap in the supplied evidence rather than an exhaustive vendor search.

Dimetix DPE-30-500 | ERDI LRF0305C | parameter verification
ParameterDimetix DPE-30-500ERDI LRF0305C
Measurement range (m)Natural surfaces 0.05...100 m (datasheet: 0.05...~100 m); Dimetix orange reflective foil 0…≥ 4000m @60% Reflectivity, Building Target ≥3000m @30% Reflectivity, 2.3×2.3m Target ≥1500m @30% Reflectivity, 0.5×1.7m Target ≥800m @30% Reflectivity, 0.2×0.3m Target
Accuracy (cm)±3.0 mm @2σ (±1.5 mm @1σ), typical; repeatability ±0.7 mm @2σ (±0.35 mm @1σ)±1 m
Update rate (Hz)Max. measuring rate 250 HzNot published
Electrical interface and protocolAnalog 0/4...20 mA programmable (max error ±0.1%); 1 digital input; 2 …Not published
Supply voltage (V)12...30 VDC; 0.5 A @24 VDC / 0…DC 3~5V
Wavelength (nm)620-690 nm (red, typical 655 n…Not published
Field of view (deg)Not publishedNot published
Published price (USD)Not publishedNot published

Evidence and limitations

Dimetix DPE-30-500 source record

Source: https://dimetix.com/wp-content/uploads/2025/08/TechnicalReferenceManual_DSeries_V116.pdf (captured , confidence high)

ERDI LRF0305C source record

SOURCE_URL: https://erdilrf.com/models/lrf0305c/
CAPTURED_AT:

≥ 4000m @60% Reflectivity, Building Target ≥3000m @30% Reflectivity, 2.3×2.3m Target ≥1500m @30% Reflectivity, 0.5×1.7m Target ≥800m @30% Reflectivity, 0.2×0.3m Target | ±1 m | DC 3~5V | ≤ 27×25×15.5mm(L×W×H)

Frequently asked questions

Is the DPE-30-500 comparison based on verified measurements?

No independent side-by-side test is supplied. The table distinguishes source-backed entries from verification gaps, and the evaluation must use comparable targets, conditions and operating modes.

Why are some DPE-30-500 comparison cells marked Not published?

The supplied parameter record lacks a usable value or complete source metadata. ERDI entries additionally require a supporting source excerpt. These are evidence gaps in this record, not zero values and not proof that the feature is absent.

How do I ask ERDI about LRF0305C?

Use the model link to review the candidate, then send the intended application, target conditions, host interface and quantity through the contact page. Request the applicable documents and a scoped assessment rather than assuming compatibility.

Discuss the ERDI candidate

Provide the required measurement function and operating conditions so the candidate can be assessed against the application. Model names and this planning association alone do not constitute a compatibility recommendation.