Once you have selected a 1,200 m module for a compact payload, four decisions account for most bring-up failures: confirming the UART signal level for the specific delivered unit, sizing the power supply for peak and inrush current rather than the average alone, choosing a window material that actually transmits at 905 nm, and following a repeatable bring-up sequence before combining the assembly. The SPD1200N2, SPD1200S2G, and LR1200E2 share several protocol properties but differ on each of these points in ways that affect wiring and test.
UART levels and baud rate
All three modules document UART-TTL communication with a default baud rate of 115,200 bps, 8 data bits, and an 8-byte distance frame. That shared description does not mean the signal levels are interchangeable with every 3.3 V or 5 V host, and the supply voltage range (3.3–5 V) is a power specification, not a signal-level specification.
For the LR1200E2, the factory confirmed in an oral answer (via the owner, 2026-11-08) that TXD and RXD accept both 3.3 V and 5 V logic. The same module has a function-enable pin, SW-SHOT (pin 6); a second factory oral answer (2026-11-11) states that when control is by serial command only, pin 6 must be held high. Neither answer has yet been updated into the printed datasheet; keep both conditions recorded in the design file and verify the connection before powering a production board.
For the SPD1200N2 and SPD1200S2G, the UART signal level is not stated in the source documentation. The SPD1200S2G datasheet includes an explicit caution: the 3.3–5 V active-high range specified for the SW-SHOT pin must not be assumed to define the UART signal levels. Ask ERDI for the electrical interface data for the delivered revision of each model before connecting either to a host.
Baud rate changes are sent as a protocol command and do not take effect until the module is restarted. The SPD1200N2 measures at 2–15 Hz adaptive; in some configurations the lower limit is 4 Hz. Confirm the delivered configuration with ERDI before you design around the lower bound.
- Ask ERDI for the UART signal level of the specific delivered unit before wiring SPD1200N2 or SPD1200S2G.
- For LR1200E2 serial-only control: hold SW-SHOT (pin 6) high (factory oral answer, 2026-11-11).
- Do not infer UART signal levels from the supply voltage range; 3.3–5 V describes the power input, not the logic levels.
- Set the host UART to 115,200 bps, 8N1; allow the module to restart before a baud-rate change takes effect.
- For SPD1200N2: confirm the measurement-frequency lower bound with ERDI before relying on a specific output rate.
Supply and peak current
All three modules accept a supply in the 3.3–5 V range. The operating-power values in the source differ in what they describe: SPD1200N2 gives average and maximum figures; LR1200E2 distinguishes short-range and maximum operating points; SPD1200S2G gives only an average figure. Use the peak operating value and the inrush transient, not the average, to size the regulator, bulk capacitance, and protection components.
| Module | Supply | Average power | Peak power | Inrush current | Startup time |
|---|---|---|---|---|---|
| SPD1200N2 | 3.3–5 V | ≈ 0.45 W | ≤ 0.75 W | Not stated in source | ≤ 200 ms |
| SPD1200S2G | 3.3–5 V | ≈ 0.65 W | Not stated | ≈ 350 mA | ≤ 200 ms |
| LR1200E2 | 3.3–5 V | ≈ 0.4 W (short-range) | ≈ 1 W | ≈ 350 mA | ≤ 200 ms |
The LR1200E2 source also documents a standby power of approximately 0.2 W and a sleep power below 1 mW. These are relevant if the payload duty-cycles the module to manage battery load; plan the switching sequence so that the host waits at least 200 ms after power is restored before sending the first measurement command. The SPD1200N2 source does not state an inrush figure; ask ERDI for this value before sizing the capacitor bank from the peak operating figure alone. When sizing bulk capacitance at the supply pin, work from the inrush current and the regulator’s minimum hold-up time rather than from the average figures in the table.
Window material and angle
All three modules operate at 905 nm ± 5 nm. A window that is visually clear is not automatically suitable at this wavelength; evaluate the specific material using its transmission data at 905 nm and the intended incidence angle, not its visible-light appearance. Ask the window supplier for measured transmission at the operating wavelength and distinguish a full-window measurement from a single-surface figure.
The receiving apertures in the source records are: SPD1200N2, Ø 6.5 mm; SPD1200S2G, 9.0 × 14.5 mm; LR1200E2, 9.2 × 14.5 mm. Leave the window’s usable clear area larger than the receiving aperture after accounting for the retaining lip, adhesive, gasket and assembly tolerances. The beam divergence values are: SPD1200N2, < 4.5 mrad; LR1200E2, < 4 mrad; SPD1200S2G, < 6 mrad. With the transmit path growing at that angular rate, verify the window usable area clears the transmit beam through the full gimbal travel, not only at the nominal pointing angle.
Tilting the window moves surface reflections out of the receive path but also changes the optical path length through the glass and the available space for baffle and seal. Evaluate any tilt by comparing the assembled payload against the bare module on a representative target at the same distance, keeping the fixture constant. A range reading that differs from the bare-module result indicates an optical effect in the window or baffle; investigate alignment and contamination as well as tilt before changing the window angle. The module’s published maximum range applies to the bare module alone and is not a guarantee for the finished assembly.
Bring-up test sequence
Test each part of the assembly independently before combining. Verify the UART connection and power supply before mounting the window; add the window and baffle as a separate step and compare readings. The command bytes below are from the source documentation; confirm the applicable revision against the ERDI interface document for the delivered unit.
- Apply power and wait at least 200 ms for the documented startup time to expire before sending any command.
- Capture the power-on self-test frame. SPD1200N2 and LR1200E2 emit a frame on startup with function byte 0x80:
55 AA 80 STA 00 00 ErrCode SUM[1:7]. STA = 1 means initialization succeeded; any other STA value indicates a fault and ErrCode identifies it. The SPD1200S2G source does not document a startup self-test frame; note this as an unconfirmed item and proceed to the first command after the startup wait. - Send a single-shot command. For SPD1200N2 and LR1200E2:
55 AA 88 FF FF FF FF 84. For SPD1200S2G the same function code 0x88 applies with the same checksum rule (SUM[3:7] on the transmit frame). Receive the 8-byte reply. - Check the reply. Verify the header bytes 55 AA, function byte 0x88, and STA = 1 (measurement successful). A STA value other than 1 means the measurement did not complete; check supply, enable pin and bench distance before troubleshooting the optics.
- Decode the distance. The raw value is DIS_H × 256 + DIS_L (both hex bytes from the reply frame); divide by 10 to get meters. Confirm the result is consistent with the bench target distance.
- Check minimum distance for LR1200E2. The source-documented minimum measuring distance is 4 m. A bench target closer than 4 m will not produce a valid result; this is a source-defined limit, not a hardware fault. SPD1200N2 and SPD1200S2G document a minimum distance of 0.2 m and 0.1 m respectively.
- Switch to continuous mode (
55 AA 89 FF FF FF FF 85). Monitor the output rate and confirm it falls within the adaptive range for the delivered configuration (LR1200E2: 2–10 Hz; SPD1200N2: confirm lower bound with ERDI). Verify frame arrival rate against the host buffer budget for the actual mode. - Send the stop command (
55 AA 8E FF FF FF FF 8A). Confirm the reply STA = 1 before switching off power or changing modes.
FAQ
What UART level does the module use?
For LR1200E2, the factory confirmed (oral, 2026-11-08) that TXD and RXD work with both 3.3 V and 5 V logic. For SPD1200N2 and SPD1200S2G, the UART signal level is not stated in the source documentation; ask ERDI for the electrical interface data for the delivered revision before wiring. Supply voltage (3.3–5 V) is a power specification, not a signal-level specification.
How much supply headroom is needed?
Size for the peak, not the average. LR1200E2 peaks at approximately 1 W with an inrush of approximately 350 mA; SPD1200S2G averages approximately 0.65 W with an inrush of approximately 350 mA; SPD1200N2 peaks at ≤ 0.75 W but its inrush figure is not stated in the source—ask ERDI before sizing. Allow at least 200 ms after applying supply before sending the first command.
Does a window shorten range?
It can. The module’s published maximum range applies to the bare module; the installed assembly must be evaluated separately on the intended targets. A window that transmits poorly at 905 nm will reduce the optical budget; a window that causes back-reflection will introduce near-distance errors. Compare the assembled payload against the bare module at a fixed bench distance to establish actual installed performance before accepting the assembly.
For model-specific drawings, electrical interface documents, inrush data and confirmation of the delivered revision, use the ERDILRF contact page.
Category pages: Laser distance sensor · Laser rangefinder module
Models mentioned in this article
- SPD1200N2905 nm · up to 1.2 km · UART · TTL · ≤5 g1 pc $90 · shipping includedSee price & buy
- LR1200E2905 nm · up to 1.2 km · UART · TTL · ≤10 g1 pc $90 · shipping includedSee price & buy