Interface
UART-TTL, Customizable
Discuss integration
SPD series
The ERDI SPD1200Z2 is a 905 nm laser rangefinder module with 1.2 km published range, 6 g weight, UART/TTL interface, from $150 per piece with free worldwide shipping. Specs verified:
905 nm Laser Rangefinder Module.
Built into your next design.
$150 USD / unitPublished unit price · Quantity options
MOQ 1 pc · Free worldwide shipping · Reply within 24 h
Standard warranty: one year
Lead time stated on your PI before payment
Shipped by DHL to customers in the US, India and Ukraine
Published price · shipping included worldwide · pay by card or PayPal, or by bank transfer. Volume price applies automatically.
Added to cart. Go to checkout →
Card or PayPal · Bank transfer · Free worldwide shipping
| Quantity | Unit price | Subtotal at first quantity |
|---|---|---|
| 1+ | $150 | $150 |
The details
Read every value with its conditions. View the model documents for integration.
| Parameter | Specification & conditions |
|---|---|
| Laser Wavelength | 905nm±5nm |
| Laser Divergence Angle | <6mrad |
| Optical Material | Aspherical Lens |
| Aperture Size | 5.0mm × 7mm |
| Ranging Range | 0.2–1,200 m; up to 1,500 m at nightNot a guaranteed range: 1,500 m applies at night under favourable conditions. Strong sunlight or low visibility may reduce range. |
| Ranging Accuracy | ±0.2 m (d ≤ 200 m); ±0.5 m (d ≤ 400 m); ±(0.5 m + 0.001d) (400 m < d < 1,200 m); d is distance in metres |
| Ranging Frequency | 2–20 Hz adaptive |
| Measurement Accuracy Rate | ≥98% |
| False Alarm Rate | ≤1% |
| Communication Interface | UART-TTL, Customizable |
| Baud Rate | Default 115200bps, Optional 9600bps |
| Supply Voltage | 3.3V~5V |
| Start-up Time | ≤200ms |
| Peak Start-up Current | ≈350mA |
| Operating Power Consumption | Average ≈0.45 W; maximum ≈0.7 W |
| Operating Temperature | −20 °C~+60 °C |
| Storage Temperature | −40 to +60 °C |
| Ingress Protection | Lens cavity IP67 |
| Laser Safety Class | IEC CLASS I |
| Dimension | 7.2 × 14.8 × 28.2 mm |
| Weight | ≈6g |
| Shock Resistance | 1000g/ms (10 times/s, optical axis direction) |
| Vibration Resistance | 5~50~5 Hz, 1 octave/min, 2.5g |
| Reliability | MTBF≥1500h |
| Parameter | Specification & conditions |
|---|---|
| 1 | SW-SHOTFunction Enable (active high) Note: Compatible with active-low control requirements |
| 2 | RXDSignal input port, Host → Ranging Module |
| 3 | TXDSignal output port, Ranging Module → Host |
| 4 | I/O (Reserved)Reserved for expansion |
| 5 | VCCPower + |
| 6 | GNDPower − |
Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.
UART-TTL, Customizable
Discuss integration3.3V~5V
Discuss integrationSPD1200Z2 905 nm Laser Rangefinder Module
SPD1200Z2 is a laser rangefinder module for OEM integration, with a published test range of 1.2 km and a UART interface. Confirm target conditions, configuration and the current datasheet before integration.
SPD1200Z2 is a thin 7.2 × 14.8 × 28.2 mm, ≈6 g 905 nm module with 0.2–1200 m catalogue range and ±0.2 m accuracy to 200 m, for slim devices that need near and far ranging.
WhatsApp about SPD1200Z2Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.
Integration library
Drawings, test conditions and application notes. Open the part you need.
Figures are reproduced from the SPD1200Z2 datasheet. Read each value together with the test condition printed beside it.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Laser Wavelength | 905nm±5nm | |
| Laser Divergence Angle | <6mrad | |
| Optical Material | Aspherical Lens | |
| Aperture Size | 5.0mm × 7mm | |
| Ranging Range | 0.2–1,200 m; up to 1,500 m at night | Not a guaranteed range: 1,500 m applies at night under favourable conditions. Strong sunlight or low visibility may reduce range. |
| Ranging Accuracy | ±0.2 m (d ≤ 200 m); ±0.5 m (d ≤ 400 m); ±(0.5 m + 0.001d) (400 m < d < 1,200 m); d is distance in metres | |
| Ranging Frequency | 2–20 Hz adaptive | |
| Measurement Accuracy Rate | ≥98% | |
| False Alarm Rate | ≤1% | |
| Communication Interface | UART-TTL, Customizable | |
| Baud Rate | Default 115200bps, Optional 9600bps | |
| Supply Voltage | 3.3V~5V | |
| Start-up Time | ≤200ms | |
| Peak Start-up Current | ≈350mA | |
| Operating Power Consumption | Average ≈0.45 W; maximum ≈0.7 W | |
| Operating Temperature | -20℃~+60℃ | |
| Storage Temperature | −40 to +60 °C | |
| Ingress Protection | Lens cavity IP67 | |
| Laser Safety Class | IEC CLASS I | |
| Dimension | 7.2 × 14.8 × 28.2 mm | |
| Weight | ≈6g | |
| Shock Resistance | 1000g/ms (10 times/s, optical axis direction) | |
| Vibration Resistance | 5~50~5 Hz, 1 octave/min, 2.5g | |
| Reliability | MTBF≥1500h | |
| Pin | Definition | Description |
| 1 | SW-SHOT | Function Enable (active high) Note: Compatible with active-low control requirements |
| 2 | RXD | Signal input port, Host → Ranging Module |
| 3 | TXD | Signal output port, Ranging Module → Host |
| 4 | I/O (Reserved) | Reserved for expansion |
| 5 | VCC | Power + |
| 6 | GND | Power − |
115200 bps default, 9600 bps optional.
2–20 Hz adaptive in the current table; confirm for your batch.
±0.5 m up to 400 m.
Taken from the SPD1200Z2 outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.
Two M1.2 screw holes beside the windows. Hole spacing and thread depth are not dimensioned on the drawing.
Request the SPD1200Z2 STEP model for your bracket design.
| Command | Send (hex) | Reply (hex) | Notes |
|---|---|---|---|
| Single measurement | 55 AA 88 FF FF FF FF 84 | 55 AA 88 STA FF DIS_H DIS_L SUM[1:7] | STA = 1: success. DIS_H/DIS_L = distance high/low byte; the reported value is 10 x the measured value. |
| Continuous measurement | 55 AA 89 FF FF FF FF 85 | 55 AA 89 STA FF DIS_H DIS_L SUM[1:7] | STA = 1: success. DIS_H/DIS_L = distance high/low byte; the reported value is 10 x the measured value. |
| Stop measurement | 55 AA 8E FF FF FF FF 8A | 55 AA 8E STA FF FF FF SUM[1:7] | STA = 1: stopped; STA = 0: failed. |
Frames follow the SPD1200Z2 user manual; every full frame has been checked against the manual's checksum rule. Open-source drivers: Drivers & wiring.
Engineering Q&A
Wiring, protocol or integration question? Ask in the ERDI engineering community.
Use the integration path that matches your host:
Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.
Inspect the model in your browser, or ask for the STEP file for your design review.
Request 3D STEP model — reply within 24 hTechnical inquiry
Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.