The ERDI SPD1200S2 is a 905 nm laser rangefinder module with 1.2 km published range, 10 g weight, UART/TTL interface, from $150 per piece with free worldwide shipping. Specs verified:
905 nm Laser Rangefinder Module.
Built into your next design.
$150 USD / unitPublished unit price · Quantity options
MOQ 1 pc · Free worldwide shipping · Reply within 24 h
Standard warranty: one year
Lead time stated on your PI before payment
Shipped by DHL to customers in the US, India and Ukraine
Published price · shipping included worldwide · pay by card or PayPal, or by bank transfer. Volume price applies automatically.
Added to cart. Go to checkout →
Card or PayPal · Bank transfer · Free worldwide shipping
| Quantity | Unit price | Subtotal at first quantity |
|---|---|---|
| 1+ | $150 | $150 |
The details
Read every value with its conditions. View the model documents for integration.
| Parameter | Specification & conditions |
|---|---|
| Laser Wavelength | 905nm±5nm |
| Laser Divergence Angle | <6mrad |
| Optical Material | Resin aspherical lens |
| Receiving Aperture | 9.0mm × 14.5mm |
| Ranging Range | 0.2–1,200 m; up to 1,500 m at nightNot a guaranteed range: 1,500 m applies at night under favourable conditions. Strong sunlight or low visibility may reduce range. |
| Ranging Accuracy | ±0.3m (≤400m)±0.5m + d × 0.1% (400m<d<1,200m) |
| Ranging Frequency | 4Hz~15Hz Adaptive |
| Measurement Accuracy Rate | ≥98% |
| False Alarm Rate | ≤1% |
| Communication Interface | UART-TTL, Customizable |
| Baud Rate | Default: 115200bps |
| Supply Voltage | 3.3V~5V |
| Start-up Time | ≤200ms |
| Instant Start Current | ≈300mA |
| Operating Power Consumption | Average ≈0.5W,Max 0.75W |
| Operating Temperature | −20 °C~+60 °C |
| Storage Temperature | −40 °C~+60 °C |
| Protection Grade | Lens cavity IP67 |
| Laser Safety Class | IEC CLASS I |
| Dimension | 24.6 × 14.45 × 26.3 mm |
| Weight | ≤10g |
| Parameter | Specification & conditions |
|---|---|
| 1 | GNDPower − |
| 2 | VCCPower + |
| 3 | I/O (Reserved)Reserved for expansion |
| 4 | TXDSignal output port, Ranging Module → Host |
| 5 | RXDSignal input port, Host → Ranging Module |
| 6 | SW-SHOTFunction Enable (active high) Note: Compatible with active-low control requirements |
Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.
UART-TTL, Customizable
Discuss integration3.3V~5V
Discuss integrationSPD1200S2 905 nm Laser Rangefinder Module
SPD1200S2 is a laser rangefinder module for OEM integration, with a published test range of 1.2 km and a UART interface. Confirm target conditions, configuration and the current datasheet before integration.
SPD1200S2 is a square 905 nm module (≤10 g) with a 0.2–1200 m catalogue range, for integrators who want very short minimum distance and ±0.3 m accuracy out to 400 m.
WhatsApp about SPD1200S2Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.
Integration library
Drawings, test conditions and application notes. Open the part you need.
Its 0.2 m minimum range is far shorter than the 4 m of the E family (LR1200E2). SPD1200Z2 offers the same catalogue range in a thinner 7.2 × 14.8 × 28.2 mm form with a faster 2–20 Hz output.
At night, under favourable conditions, it can reach up to 1,500 m; this is not a guaranteed range.
Published unit prices start at $150 at 1+ pieces; see Volume Pricing for all quantity bands.
Figures are reproduced from the SPD1200S2 datasheet. Read each value together with the test condition printed beside it.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Dimensions | 24.6 × 14.45 × 26.3 mm | |
| Measurement range | 0.2–1,200 m; up to 1,500 m at night | Not a guaranteed range: 1,500 m applies at night under favourable conditions. Strong sunlight or low visibility may reduce range. |
0.2 m according to the catalogue range.
Only stated as a night-time maximum under special conditions; specify 1200 m.
Z2 is thinner and faster; S2 is square and easier to bracket.
Taken from the SPD1200S2 outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.
Mounting-hole dimensions for this model are supplied with the outline drawing and STEP model on request.
Request the SPD1200S2 STEP model for your bracket design.
| Command | Send (hex) | Reply (hex) | Notes |
|---|---|---|---|
| Single measurement | 55 AA 88 FF FF FF FF 84 | 55 AA 88 STA FF DIS_H DIS_L SUM[1:7] | STA = 1: success. DIS_H/DIS_L = distance high/low byte; the reported value is 10 x the measured value. |
| Continuous measurement | 55 AA 89 FF FF FF FF 85 | 55 AA 89 STA FF DIS_H DIS_L SUM[1:7] | STA = 1: success. DIS_H/DIS_L = distance high/low byte; the reported value is 10 x the measured value. |
| Stop measurement | 55 AA 8E FF FF FF FF 8A | 55 AA 8E STA FF FF FF SUM[1:7] | STA = 1: stopped; STA = 0: failed. |
Frames follow the SPD1200S2 user manual; every full frame has been checked against the manual's checksum rule. Open-source drivers: Drivers & wiring.
Engineering Q&A
Wiring, protocol or integration question? Ask in the ERDI engineering community.
Use the integration path that matches your host:
Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.
Inspect the model in your browser, or ask for the STEP file for your design review.
Request 3D STEP model — reply within 24 hTechnical inquiry