Integration
Use the integration path that matches your host:

Erbium-glass laser sources
The ERDI ER500 is a 1535 nm pulsed laser source with 12 g weight, from $350 per piece with free worldwide shipping. Specs verified:
1535 nm Erbium-Glass Laser Source.
Built into your next design.
1 pc $350501+ pcs from $240Published unit prices, shipping included · Quantity options
MOQ 1 pc · Free worldwide shipping · Reply within 24 h
Standard warranty: one year
Lead time stated on your PI before payment
Shipped by DHL to customers in the US, India and Ukraine
Published price · shipping included worldwide · pay by card or PayPal, or by bank transfer. Volume price applies automatically.
Added to cart. Go to checkout →
Card or PayPal · Bank transfer · Free worldwide shipping
| Quantity | Unit price | Subtotal at first quantity |
|---|---|---|
| 1–10 | $350 | $350 |
| 11–30 | $330 | $3,630 |
| 31–50 | $320 | $9,920 |
| 51–200 | $310 | $15,810 |
| 201–500 | $280 | $56,280 |
| 501+ | $240 | $120,240 |
The details
Read every value with its conditions. View the model documents for integration.
| Parameter | Specification & conditions |
|---|---|
| Model | ER500 |
| Laser Wavelength | 1535nm |
| Parameter | Specification & conditions |
|---|---|
| Laser classification | Class 1 |
| Parameter | Specification & conditions |
|---|---|
| Pulse energy | ≥500 μJ |
| Laser Pulse width | 6 ns |
| Drive pulse width | ≤2.4 ms |
| Pulse repetition rate | 1~10Hz |
| Pulse stability | 10% |
| Raw Beam Diameter | 0.3 mm |
| Beam divergence angle | ≤ 7 mrad |
| Beam Mode | TEM00 |
| Operating temperature | −40 °C ~ +65 °C |
| Storage temperature | −55 °C ~+ 75 °C |
| Dimension (mm) | 35 × 8 × 6.8 mm |
| Weight | 12 g |
| Voltage | 2 V |
| Electric current | 20 A |
| Shock | 1500 G, 0.5 ms |
| Vibration | 20~2000 Hz/20 G |
| Lifetime | >1million shots |
Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.
ER500 1535 nm Erbium-Glass Laser Source
ER500 is a laser rangefinder module for OEM integration. Confirm target conditions, configuration and the current datasheet before integration.
ER500 is a bare 1535 nm erbium-glass pulsed laser source for engineers who design their own rangefinder board and want ≥500 µJ per pulse in the same 35 × 8 × 6.8 mm package as the 400 µJ part.
WhatsApp about ER500Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.
Integration library
Drawings, test conditions and application notes. Open the part you need.
ER500 shares its 35 × 8 × 6.8 mm, 12 g footprint with ER400, but matching package dimensions and mass do not establish board or pin compatibility. Confirm pin assignment, controlled drive requirements, optical configuration and mechanical drawings for both ordered versions before substitution. Move to ER500 when your link budget needs the extra pulse energy (≥500 µJ versus 400 µJ) and you can live with the 1–10 Hz repetition range.
If the optical bench is tight, ER300 (≥300 µJ) is 25 mm long and 8.5 g. If you need more energy, ER800 and ER900 step up to ≥800 µJ and ≥900 µJ but grow to 40 × 8 × 7.5 mm and 18 g. The millijoule parts (ER2000, ER4000) use a 60 × 25 × 13.5 mm body and a different drive.
Price follows the same ladder: ER500 is listed from $250 per unit, against $230 for ER400 and $1,050 for ER800.
Figures are reproduced from the ER500 datasheet. Read each value together with the test condition printed beside it.
ER500 is part of the 1535 nm erbium-glass pulsed laser family. Its current PDF lists pulse energy ≥500 μJ and optical pulse width 6 ns. Repetition-rate status is shown separately in the table. These are the source's distinct specifications; none establishes the distance or accuracy of a finished instrument.
| Parameter | Current PDF value |
|---|---|
| Model | ER500 |
| Laser Wavelength | 1535nm |
| Laser classification | Class 1 |
| Pulse energy | ≥500 μJ |
| Laser Pulse width | 6 ns |
| Drive pulse width | ≤2.4 ms |
| Pulse repetition rate | 1~10Hz |
| Pulse stability | 10% |
| Raw Beam Diameter | 0.3 mm |
| Beam divergence angle | ≤ 7 mrad |
| Beam Mode | TEM00 |
| Operating temperature | -40 ℃ ~ +65 ℃ |
| Storage temperature | -55 ℃ ~+ 75℃ |
| Dimension (mm) | 35×8×6.8 mm |
| Weight | 12 g |
| Voltage | 2 V |
| Electric current | 20 A |
| Shock | 1500 G, 0.5 ms |
| Vibration | 20~2000 Hz/20 G |
| Lifetime | >1million shots |
The recorded raw beam diameter is 0.3 mm and divergence is ≤ 7 mrad. The current specification table does not state the divergence's full-angle/half-angle convention or the beam-width measurement method. Those definitions remain unspecified until a beam report confirms them. The beam-mode entry does not, by itself, supply a measured M² value.
Values above were checked against the current model PDF, including its inequality signs and stated measurement qualifiers. Source entries of “Class 1” require the corresponding classification report; shock, vibration and lifetime entries likewise need their stated test conditions. Missing tolerances and statistics are not reconstructed from another model or a paper.

No. It is the laser source only. You still need the pump driver, receiver, timing electronics and optics. For a finished module, look at the 1535 nm C-line rangefinders.
The package dimensions and mass match (35 × 8 × 6.8 mm, 12 g). Check that your driver can supply the 20 A drive current and that your thermal design covers the higher pulse energy.
The module document states Class 1, but classification belongs to the complete, evaluated configuration. Your finished instrument needs its own assessment.
No. The reviewed ER500 brochure's model-specific table lists 1535 nm, while its heading uses 1.54 µm. The general principle section describes pump light as “typically around 940 nm”; that is not the model's stated laser output. Neither this generic explanation nor the accompanying schematic identifies the pump diode fitted to an ordered ER500, its bill of materials, electrical interface or approved drive conditions. Use the applicable current documentation for the supplied configuration to confirm those details before selecting a pump or driver.
Taken from the ER500 outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.
Two Φ2.4 mm mounting holes in the side lugs, 12 mm apart centre to centre. Recommended fastening torque 0.2 N·m. Screw size is not stated on the drawing.
Request the ER500 STEP model for your bracket design.
Engineering Q&A
Wiring, protocol or integration question? Ask in the ERDI engineering community.
Use the integration path that matches your host:
Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.
Inspect the model in your browser, or ask for the STEP file for your design review.
Request 3D STEP model — reply within 24 hTechnical inquiry
Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.