Integration
Use the integration path that matches your host:

Erbium-glass laser sources
The ERDI ER100 is a 1.54 µm pulsed laser source with 7 g weight, from $120 per piece with free worldwide shipping. Specs verified:
1.54 µm Erbium-Glass Laser Source.
Built into your next design.
1 pc $1201,001+ pcs from $70Published unit prices, shipping included · Quantity options
MOQ 1 pc · Free worldwide shipping · Reply within 24 h
Standard warranty: one year
Lead time stated on your PI before payment
Shipped by DHL to customers in the US, India and Ukraine
Published price · shipping included worldwide · pay by card or PayPal, or by bank transfer. Volume price applies automatically.
Added to cart. Go to checkout →
Card or PayPal · Bank transfer · Free worldwide shipping
| Quantity | Unit price | Subtotal at first quantity |
|---|---|---|
| 1–10 | $120 | $120 |
| 11–30 | $115 | $1,265 |
| 31–500 | $100 | $3,100 |
| 501–1000 | $80 | $40,080 |
| 1001+ | $70 | $70,070 |
The details
Read every value with its conditions. View the model documents for integration.
| Parameter | Specification & conditions |
|---|---|
| Model | ER100 |
| Laser Wavelength | 1.54 μm |
| Parameter | Specification & conditions |
|---|---|
| Laser classification | Class 1 |
| Parameter | Specification & conditions |
|---|---|
| Pulse energy | ≥100 μJ |
| Laser Pulse width | 6 ns |
| Drive pulse width | ≤2.4 ms |
| Pulse repetition rate | 1~10Hz |
| Pulse stability | 10% |
| Raw Beam Diameter | 0.3 mm |
| Beam divergence angle | ≤ 8 mrad |
| Beam Mode | TEM00 |
| Operating temperature | −40 °C ~ +65 °C |
| Storage temperature | −55 °C ~+ 75 °C |
| Dimension (mm) | 21 × 8 × 6.8 mm |
| Weight | 7 g |
| Voltage | 2 V |
| Electric current | 8 A |
| Shock | 1500 G, 0.5 ms |
| Vibration | 20~2000 Hz/20 G |
| Service life | ≥1million shots |
Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.
ER100 1.54 µm Erbium-Glass Laser Source
ER100 1.54 µm Erbium-Glass Laser Source. Compare pulse energy, pulse width, repetition rate, drive requirements and model documents.
ER100 is the entry 1535 nm erbium-glass pulsed source (≥100 µJ, 21 × 8 × 6.8 mm, 7 g) for compact rangefinder designs where cost per unit matters more than maximum reach.
WhatsApp about ER100Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.
Integration library
Drawings, test conditions and application notes. Open the part you need.
ER100 and ER200 share the 21 × 8 × 6.8 mm, 7 g package. ER200 raises pulse energy to 200 µJ at a fixed 10 Hz; ER100 keeps an adjustable 1–10 Hz rate and ≤8 mrad divergence. The list price gap is small ($70 against $80), so the choice is usually driven by link budget.
For the smallest possible emitter, MINI-100 offers the same energy class in 2.5 g. For more margin on dark targets, ER300 adds ≥300 µJ in a 25 mm-long body.
ER100 is the referenced source of the LRF0310C rangefinder module.
Figures are reproduced from the ER100 datasheet. Read each value together with the test condition printed beside it.
ER100 is part of the 1535 nm erbium-glass pulsed laser family. Its current PDF lists pulse energy ≥100 μJ and optical pulse width 6 ns. Repetition-rate status is shown separately in the table. These are the source's distinct specifications; none establishes the distance or accuracy of a finished instrument.
| Parameter | Current PDF value |
|---|---|
| Model | ER100 |
| Laser Wavelength | 1.54 μm |
| Laser classification | Class 1 |
| Pulse energy | ≥100 μJ |
| Laser Pulse width | 6 ns |
| Drive pulse width | ≤2.4 ms |
| Pulse repetition rate | 1~10Hz |
| Pulse stability | 10% |
| Raw Beam Diameter | 0.3 mm |
| Beam divergence angle | ≤ 8 mrad |
| Beam Mode | TEM00 |
| Operating temperature | -40 ℃ ~ +65 ℃ |
| Storage temperature | -55 ℃ ~+ 75℃ |
| Dimension (mm) | 21×8×6.8 mm |
| Weight | 7 g |
| Voltage | 2 V |
| Electric current | 8 A |
| Shock | 1500 G, 0.5 ms |
| Vibration | 20~2000 Hz/20 G |
| Service life | ≥1million shots |
Lifetime: the current PDF table states ≥1 million shots, while its introduction states ≥10 million. The table value is displayed; the ordered lifetime rating needs confirmation. No 10-million-shot rating is asserted here.
The recorded raw beam diameter is 0.3 mm and divergence is ≤ 8 mrad. The current specification table does not state the divergence's full-angle/half-angle convention or the beam-width measurement method. Those definitions remain unspecified until a beam report confirms them. The beam-mode entry does not, by itself, supply a measured M² value.
Values above were checked against the current model PDF, including its inequality signs and stated measurement qualifiers. Source entries of “Class 1” require the corresponding classification report; shock, vibration and lifetime entries likewise need their stated test conditions. Missing tolerances and statistics are not reconstructed from another model or a paper.

Same footprint and weight. ER200 gives 200 µJ at 10 Hz; ER100 gives ≥100 µJ with a 1–10 Hz range. Choose ER200 when the target is dark or small, ER100 when cost and variable rate matter.
No, it is the transmitter only. LRF0310C is a finished module built around it.
It is the supported pulse repetition range. Your update rate can be lower, which reduces average power and heat.
Taken from the ER100 outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.
Two Φ2.4 mm mounting holes in the side lugs, 12 mm apart centre to centre. Screw size is not stated on the drawing.
Request the ER100 STEP model for your bracket design.
Engineering Q&A
Wiring, protocol or integration question? Ask in the ERDI engineering community.
Use the integration path that matches your host:
Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.
Inspect the model in your browser, or ask for the STEP file for your design review.
Request 3D STEP model — reply within 24 hTechnical inquiry
Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.