The ERDI LRF0306C is a 1535 nm laser rangefinder module with 4 km published range, 14 g weight, UART/TTL interface, from $500 per piece with free worldwide shipping. Specs verified:
1535 nm Laser Rangefinder Module.
Built into your next design.
1 pc $500500+ pcs from $300Published unit prices, shipping included · Quantity options
MOQ 1 pc · Free worldwide shipping · Reply within 24 h
Standard warranty: one year
Lead time stated on your PI before payment
Shipped by DHL to customers in the US, India and Ukraine
Published price · shipping included worldwide · pay by card or PayPal, or by bank transfer. Volume price applies automatically.
Added to cart. Go to checkout →
Card or PayPal · Bank transfer · Free worldwide shipping
| Quantity | Unit price | Subtotal at first quantity |
|---|---|---|
| 1–19 | $500 | $500 |
| 20–100 | $450 | $9,000 |
| 101–299 | $400 | $40,400 |
| 300–499 | $350 | $105,000 |
| 500+ | $300 | $150,000 |
The details
Read every value with its conditions. View the model documents for integration.
| Parameter | Specification & conditions |
|---|---|
| Laser Wavelength | 1535±5nm |
| Module laser-safety statement | Class I stated in the module document. Final accessible-emission classification applies to the complete configuration. |
| Divergence Angle | ≤0.6 mrad |
| Laser Energy | ≥100 μJ |
| Field of view (FOV) | Approximately 7.4 mrad |
| Maximum Measuring Range (Visibility > 8km) | ≥ 4,000m @60% Reflectivity, Building Target ≥3,000m @30% Reflectivity, 2.3 × 2.3m Target ≥1,500m @30% Reflectivity, 0.5 × 1.7m Target ≥800m @30% Reflectivity, 0.2 × 0.3m TargetVisibility > 8km |
| Minimum Range | ≤10 m |
| Ranging Frequency | 1Hz ~3Hz |
| Multi-Target Detection | Up to 3 targets |
| Ranging Accuracy | ±1 m |
| Accuracy Rate | ≥98% |
| False Alarm Rate | ≤1% |
| Interface Type | UART(TTL 3.3V) |
| Power Supply Voltage | DC 3~5V |
| Standby Power Consumption (Full Temperature Range) | ≤10mW (Power on pulled low) |
| Operating power consumption — full temperature range | 5 V: ≤0.9 W at 1 Hz; <1.1 W at 3 Hz |
| Peak Power Consumption | ≤3W |
| Start-up Time | ≤350ms (After startup, response time <20 ms) |
| Weight | ≤14 ±1 g |
| Dimensions | ≤ 27 × 25 × 15.5mm(L×W×H) |
| Shock | 1200g, 1ms |
| Vibration | 5~50~5 Hz, 1 octave/min, 2.5g |
| Operating Temperature | −40 ~ +70 °C |
| Storage Temperature | −45 ~ +70 °C |
| Reliability | MTBF>1500h |
| Pin | DefinitionDescription |
| 1 | POWER_ONModule Power Switch, TTL 3.3V Level; Module On (>2.7V), Module Off (<0.3V) |
| 2 | UART_RXSerial Port Receiver, TTL 3.3V Level |
| 3 | UART_TXSerial Port Transmitter, TTL 3.3V Level |
| 4 | NC |
| 5 | Power PositivePower Supply, 3~5V |
| 6 | GNDSerial Port Ground |
Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.
≤ 27 × 25 × 15.5mm(L×W×H)
Discuss integrationUART(TTL 3.3V)
Discuss integrationLRF0306C 1535 nm Laser Rangefinder Module
LRF0306C is a laser rangefinder module for UAV payloads, with a published test range of 4 km and a UART interface. Confirm target conditions, configuration and the current datasheet before integration.
LRF0306C is the low-rate twin of LRF0305C: the same 27 × 25 × 15.5 mm, ≤14 g 1535 nm module limited to 1–3 Hz for battery products that range a few times per second at most.
WhatsApp about LRF0306CPublished unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.
Integration library
Drawings, test conditions and application notes. Open the part you need.
Optics, accuracy (±1 m), minimum range (≤10 m) and reference range (≥3000 m on a 30% building target) match LRF0305C. The difference is the 1–3 Hz ceiling and an operating draw below 1.1 W at 3 Hz.
If you need a higher rate later, LRF0305C is a drop-in alternative in the same footprint. For 4.5–16 V systems, LRF0310C is the next size up.
Published unit prices start at $300 at 500+ pieces; see Volume Pricing for all quantity bands.
Figures are reproduced from the LRF0306C datasheet. Read each value together with the test condition printed beside it.
LRF0306C is a 1535 nm pulsed distance-measurement module. Its assigned laser source is MINI-100; receiver-component data below come from the supplied APD-A13B001 R01 document. The three specification levels describe different assemblies and measurement conditions.
|
Laser Wavelength |
1535±5nm |
| Module laser-safety statement | Class I stated in the module document. Final accessible-emission classification applies to the complete configuration. |
|---|---|
|
Divergence Angle |
≤0.6 mrad |
|
Laser Energy |
≥100 μJ |
| Field of view (FOV) | Approximately 7.4 mrad |
|
Maximum Measuring Range (Visibility > 8km) |
≥ 4000m @60% Reflectivity, Building Target ≥3000m @30% Reflectivity, 2.3×2.3m Target ≥1500m @30% Reflectivity, 0.5×1.7m Target ≥800m @30% Reflectivity, 0.2×0.3m Target |
|
Minimum Range |
≤10 m |
|
Ranging Frequency |
1Hz ~3Hz |
|
Multi-Target Detection |
Up to 3 targets |
|
Ranging Accuracy |
±1 m |
|
Accuracy Rate |
≥98% |
|
False Alarm Rate |
≤1% |
|
Interface Type |
UART(TTL 3.3V) |
|
Power Supply Voltage |
DC 3~5V |
|
Standby Power Consumption (Full Temperature Range) |
≤10mW (Power on pulled low) |
|
|
≤0.8W (Power on pulled high) |
| Operating power consumption — full temperature range | 5 V: ≤0.9 W at 1 Hz; <1.1 W at 3 Hz |
|
|
5V,<1. 1W@3Hz |
|
Peak Power Consumption |
≤3W |
|
Start-up Time |
≤350ms (After startup, response time <20 ms) |
| Weight | ≤14 ±1 g |
|
Dimensions |
≤ 27×25×15.5mm(L×W×H) |
|
Shock |
1200g, 1ms |
|
Vibration |
5~50~5 Hz, 1 octave/min, 2.5g |
|
Operating Temperature |
-40 ~ +70℃ |
|
Storage Temperature |
-45 ~ +70℃ |
|
Reliability |
MTBF>1500h |
|
Pin |
Definition |
Description |
|
1 |
POWER_ON |
Module Power Switch, TTL 3.3V Level; Module On (>2.7V), Module Off (<0.3V) |
|
2 |
UART_RX |
Serial Port Receiver, TTL 3.3V Level |
|
3 |
UART_TX |
Serial Port Transmitter, TTL 3.3V Level |
|
4 |
NC |
|
|
5 |
Power Positive |
Power Supply, 3~5V |
|
6 |
GND |
Serial Port Ground |



| Parameter | Value |
|---|---|
| Optical wavelength | 1535 nm |
| Pulse energy | ≥100 µJ |
| Optical pulse width | 3.5 ns |
| Repetition rate | 1–10 Hz |
| Raw beam diameter | 0.3 mm |
| Initial beam divergence | ≤10 mrad |
| Transverse mode | TEM00 |
| Operating temperature | −40 to +65 °C |
| Storage temperature | −55 to +85 °C |
| Package dimensions | 14.5 × 6.3 × 4.37 mm |
| Mass | 2.5 g |
| Drive pulse width | ≤1 ms |
| Component electrical entry | 2 V, 12 A |
| Pulse stability | 10% (definition/statistical method not stated) |
| Shock / vibration entries | 1500 G, 0.5 ms / 20–2000 Hz, 20 G; tested to the factory environmental test procedure (details on request) |
| Stated service life | ≥10 million shots; test conditions not supplied |
The electrical entries describe the component drive, not the module supply input. Drive conditions and pulse-width definitions must follow the component document and the individual factory record. An optical pulse-width value is not a pump-drive duration.
Small screens: swipe the table horizontally to read all measurement conditions.
| Parameter | Value | Measurement condition / scope |
|---|---|---|
| Device / active diameter | APD-A13B001 R01 / 200 µm | Supplied APD200 document, p1 |
| Detector spectral response interval | 800–1700 nm | Detector response; not the filter passband |
| Responsivity | 0.9 A/W minimum; 1.0 A/W typical | λ = 1550 nm; incident power = 1 µW; M = 1 |
| Dark current | 8 nA typical; 50 nA maximum | VR = VBR − 3 V; incident power = 0 |
| Multiplication factor | M ≥10 / M ≥30 | λ = 1550 nm; 1 µW; respectively VBR − 3 V / VBR − 1 V |
| −3 dB bandwidth | 0.6 GHz minimum; 1.25 GHz typical | M = 10; RL = 50 Ω |
| Breakdown voltage | 35–50 V | Reverse current = 10 µA; incident power = 0 |
| Capacitance | 1.8 pF typical; 2.0 pF maximum | VR = VBR − 3 V; f = 1 MHz |
| Breakdown temperature coefficient | 0.05 minimum / 0.11 typical / 0.15 maximum V/°C | Reverse current = 10 µA; dark; −55 to +85 °C |
| Operating / storage temperature | −40 to +85 °C / −55 to +125 °C | Component absolute-maximum table; not module environmental ratings |
| Maximum bias | VBR | Absolute maximum, not a recommended operating setpoint |
| Maximum forward / reverse current | 5 mA / 3 mA | Absolute maximum ratings, not continuous design targets |
| Filter centre wavelength | 1535 ±5 nm | Supplied filter table, p3 |
| Filter FWHM | <37 nm | Full width at half maximum |
| Transmission at centre wavelength | >90% | Filter specification, not total receiver throughput |
| Blocking specification | T <1%; source lists 400–1750 nm | Stop-band/transition edges are not numerically defined; the stated blocking span is not a guarantee at every wavelength. |
| Optical surface quality | 60/40 | Source label: surface quality; not a transmission value |
Responsivity is measured at 1550 nm; a value measured there is not silently relabeled as a measured 1535 nm value. Absolute maxima are stress limits. The filter document includes an illustrative spectrum, but does not define numerical transition edges or off-axis performance. No additional spectral guarantee is inferred.
Lower operating power for products that never need continuous fast updates.
Both list 27 × 25 × 15.5 mm and ≤14 g; confirm with the drawing supplied for your order.
MINI-100, the same as LRF0305C.
Taken from the LRF0306C outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.
Two M1.6 threaded mounting holes, 3.5 mm deep, on the front face either side of the emitter window. Hole spacing is not dimensioned on the drawing; the datasheet includes a recommended bracket cut-out.
Request the LRF0306C STEP model for your bracket design.
| Command | Send (hex) | Reply (hex) | Notes |
|---|---|---|---|
| Single measurement | EE 16 02 03 02 05 | — | Reply: EE 16 06 03 02 STATUS INT_H INT_L DEC CS. Distance (m) = INT_H x 256 + INT_L + DEC x 0.1. STATUS 0x04 = out of range. |
| Continuous measurement | EE 16 02 03 04 07 | — | Reply (repeated): EE 16 06 03 04 STATUS INT_H INT_L DEC CS. Distance (m) = INT_H x 256 + INT_L + DEC x 0.1. STATUS 0x04 = out of range. |
| Stop measurement | EE 16 02 03 05 08 | EE 16 02 03 05 08 | Reply echoes the command. |
| Self-test | EE 16 02 03 01 04 | — | Reply: EE 16 06 03 01 S3 S2 S1 S0 CS (status bytes). |
| First-target mode | EE 16 03 03 03 01 07 | EE 16 02 03 03 06 | 02 = last target, 03 = multi-target. |
| Read serial number | EE 16 02 03 A9 AC | — |
Frames follow the LRF0306C user manual; every full frame has been checked against the manual's checksum rule. Open-source drivers: Drivers & wiring.
Engineering Q&A
Wiring, protocol or integration question? Ask in the ERDI engineering community.
Use the integration path that matches your host:
Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.
Inspect the model in your browser, or ask for the STEP file for your design review.
Request 3D STEP model — reply within 24 hTechnical inquiry
Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.