Mechanical fit
Ø23 × 40 mm (Cylindrical; use the drawing tolerances.)
Discuss integration
LRF A series
The ERDI LRF1200A1 is a 905 nm laser rangefinder module with 1.2 km published range, 18 g weight, UART/TTL interface, from $90 per piece with free worldwide shipping. Specs verified:
905 nm Laser Rangefinder Module.
Built into your next design.
1 pc $90501+ pcs from $35Published unit prices, shipping included · Quantity options
MOQ 1 pc · Free worldwide shipping · Reply within 24 h
Standard warranty: one year
Lead time stated on your PI before payment
Shipped by DHL to customers in the US, India and Ukraine
Published price · shipping included worldwide · pay by card or PayPal, or by bank transfer. Volume price applies automatically.
Added to cart. Go to checkout →
Card or PayPal · Bank transfer · Free worldwide shipping
| Quantity | Unit price | Subtotal at first quantity |
|---|---|---|
| 1–30 | $90 | $90 |
| 31–200 | $70 | $2,170 |
| 201–500 | $50 | $10,050 |
| 501+ | $35 | $17,535 |
LRF1200A1 is a 905 nm laser rangefinder module from ERDI LASER. Published range: 5–1200 m. Ranging accuracy: ±1 m (5 m ≤ L ≤ 100 m); ±(1 + 0.004L) m (L > 100 m). Interface: UART, 3.3 V TTL. From $35 per unit, shipping included (lowest published tier, 501+ pieces; see the volume table below). Updated: 2026-11-06.
| Item | LRF1200A1 | LR1200E4 |
|---|---|---|
| Range | 5–1200 m | 4–1200 m |
| Accuracy | ±1 m (5 m ≤ L ≤ 100 m); ±(1 + 0.004L) m (L > 100 m) | ±1 m (D ≤ 400 m); ±(1 + 0.001D) m (D > 400 m) |
| Beam divergence | — | < 4 mrad (small laser spot) |
| Interface | UART, 3.3 V TTL | UART-TTL |
| Supply | 3.3 V ± 0.1 V | 3.3–5 V |
| Size | Ø23 × 40 mm | 25.7 × 14.2 × 26.2 mm |
| Published price | From $35 USD / unit | From $35 USD / unit |
Related models: LR1200E4.
The details
Read every value with its conditions. View the model documents for integration.
| Parameter | Specification & conditions |
|---|---|
| Laser wavelength | 905 nm |
| Measurement range | 5–1,200 mBuilding target; the source table gives ≥5–1200 m. |
| Ranging accuracy | ±1 m (5 m ≤ L ≤ 100 m); ±(1 + 0.004L) m (L > 100 m)L is distance in meters. |
| Display resolution | 0.1 mReporting increment, not ranging accuracy. |
| Measurement update rate | 1–3 Hz |
| Communication interface | UART, 3.3 V TTL |
| Supply voltage | 3.3 V ± 0.1 V |
| Standby power consumption | ≤400 mW |
| Operating power consumption | ≤1.5 W |
| Startup time | ≤500 ms |
| Dimensions | Ø23 × 40 mmCylindrical; use the drawing tolerances. |
| Weight | 18 g |
| Operating temperature | −20 °C to +60 °C |
| Storage temperature | −55 °C to +65 °C |
| Ingress protection | IP67Lens only. |
| Laser safety class | Class 1As stated in the model manual; finished-equipment assessment is separate. |
| Transmitter lens diameter | Ø6.6 mm |
| Receiver lens diameter | Ø18 mm |
Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.
Ø23 × 40 mm (Cylindrical; use the drawing tolerances.)
Discuss integrationUART, 3.3 V TTL
Discuss integration3.3 V ± 0.1 V
Discuss integrationLRF1200A1 905 nm Laser Rangefinder Module
LRF1200A1 is a laser rangefinder module for OEM integration, with a published test range of 1.2 km and a UART interface. Confirm target conditions, configuration and the current datasheet before integration.
LRF1200A1 is an 18 g cylindrical 905 nm module listing 5–1200 m on buildings at 1–3 Hz and standby power ≤400 mW, for low-rate handheld and fixed products. Several source documents disagree, so we confirm the delivered version before quotation.
WhatsApp about LRF1200A1Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.
Integration library
Drawings, test conditions and application notes. Open the part you need.
For a published, consistent envelope at the same range, the E family (LR1200E2, LR1200E4) is the safer choice for new designs.
If you need a cylinder, LR1200D23 (Ø23 × 45.6 mm) lists IP67 lens protection and 2–10 Hz.
Published unit prices start at $35 at 501+ pieces; see Volume Pricing for all quantity bands.
Figures are reproduced from the LRF1200A1 datasheet. Read each value together with the test condition printed beside it.
| Parameter | Value | Conditions / notes |
|---|---|---|
| Laser wavelength | 905 nm | — |
| Measurement range | 5–1200 m | Building target; the source table gives ≥5–1200 m. |
| Ranging accuracy | ±1 m (5 m ≤ L ≤ 100 m); ±(1 + 0.004L) m (L > 100 m) | L is distance in meters. |
| Display resolution | 0.1 m | Reporting increment, not ranging accuracy. |
| Measurement update rate | 1–3 Hz | — |
| Communication interface | UART, 3.3 V TTL | — |
| Supply voltage | 3.3 V ± 0.1 V | — |
| Standby power consumption | ≤400 mW | — |
| Operating power consumption | ≤1.5 W | — |
| Startup time | ≤500 ms | — |
| Dimensions | Ø23 × 40 mm | Cylindrical; use the drawing tolerances. |
| Weight | 18 g | — |
| Operating temperature | −20 °C to +60 °C | — |
| Storage temperature | −55 °C to +65 °C | — |
| Ingress protection | IP67 | Lens only. |
| Laser safety class | Class 1 | As stated in the model manual; finished-equipment assessment is separate. |
| Transmitter lens diameter | Ø6.6 mm | — |
| Receiver lens diameter | Ø18 mm | — |
The host uses the serial communication protocol to operate the ranging module. The low-power mode turns the controller off, so it does not respond to normal commands while asleep.
The manual describes an active-low enable input for normal operation and a high level for low-power mode. Use the LRF1200A1 interface and timing definitions rather than an E-series wiring assumption.
| Pin | Signal | Function |
|---|---|---|
| 1 | GND | Power ground |
| 2 | Power Supply | 3.3 V DC input; specified supply tolerance: ±0.1 V |
| 3 | NC | Not connected |
| 4 | TTL_TXD | Transmit data: module → host; 3.3 V TTL |
| 5 | TTL_RXD | Receive data: host → module; 3.3 V TTL |
| 6 | Enable Pin | Active low: normal operation. High level: low-power mode. |
Use the drawing and its tolerances for installation. This drawing is reproduced directly from the current LRF1200A1 user manual.
Both appear in source documents. We confirm the delivered drawing before you order.
Not until confirmed; the current table gives 3.3 V ± 0.1 V.
±1 m from 5 m to 100 m and ±(1 + 0.004L) m beyond.
Taken from the LRF1200A1 outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.
Mounting-hole dimensions for this model are supplied with the outline drawing and STEP model on request.
Request the LRF1200A1 STEP model for your bracket design.
| Command | Send (hex) | Reply (hex) | Notes |
|---|---|---|---|
| Single measurement | 55 AA 88 FF FF FF FF 84 | 55 AA 88 STA FF DIS_H DIS_L SUM[1:7] | STA = 1: success. DIS_H/DIS_L = distance high/low byte; the reported value is 10 x the measured value. |
| Stop measurement | 55 AA 8E FF FF FF FF 8A | 55 AA 8E STA FF FF FF SUM[1:7] | STA = 1: stopped; STA = 0: failed. |
Frames follow the LRF1200A1 user manual; every full frame has been checked against the manual's checksum rule. Open-source drivers: Drivers & wiring.
Engineering Q&A
Answered by ERDI engineers in the community.
Use the integration path that matches your host:
Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.
Inspect the model in your browser, or ask for the STEP file for your design review.
Request 3D STEP model — reply within 24 hTechnical inquiry
Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.