Skip to main content
Explore ERDILRF
ERDILRF LaserOptics. Electronics. Integration.
Products
905 nm sensors & rangefindersLR seriesSPD seriesH seriesVB seriesLRF A seriesOther product platforms1.54 µm laser sources1535 nm rangefindersAll products
Applications
Application overviewOptical observationCivil UAVsSite monitoringIndustrial sensingHandheld instrumentsField measurement
Insights
Product SpotlightEngineering knowledgeProduct filmsInside ERDILRF
Support
Technical supportFrequently asked questionsModel selectorContact our team
Downloads
All downloadsDrivers & integrationDeveloper docsEngineering community (Q&A)Specifications & CAD
How to buy
Samples & quotationsPrice listCompare modulesDealer programRequest a sample
Company
About ERDILRFCertificatesContact usPrivacy policyTerms
Talk to Sales

Press ↑↓ to move, Enter to open, Esc to close.

LRF0405C is a 1535 +/- 5 nm laser rangefinder module from ERDI LASER. Published range: 4,000 m or more at 30% reflectance and visibility of at least 6 km. Ranging accuracy: +/-2 m. Interface: UART, 3.3 V TTL level. From $400 per unit, shipping included (lowest published tier, 500+ pieces; see the volume table below). Updated: 2026-11-06.

How LRF0405C differs from neighboring models

ItemLRF0405CLRF0815CLRF0305C
Range4,000 m or more at 30% reflectance and visibility of at least 6 km≥8,000 m to a 2.3 m x 2.3 m target, 30% reflectance, visibility ≥10 km—
Accuracy+/-2 m±2 m±1 m
Beam divergence0.6 mrad or less≤0.3 mrad≤0.6 mrad
InterfaceUART, 3.3 V TTL levelRS-422; TTL optionalUART(TTL 3.3V)
Supply—12 V DCDC 3~5V
Size48 x 30.5 x 21 mm65 x 46 x 86 mm≤ 27×25×15.5mm(L×W×H)
Published priceFrom $400 USD / unitFrom $900 USD / unitFrom $300 USD / unit

Related models: LRF0815C, LRF0305C.

LRF0405C frequently asked questions

What is the measurement range of the LRF0405C?
The published range is 4,000 m or more at 30% reflectance and visibility of at least 6 km. Actual reach depends on target reflectivity, size and visibility.
What laser wavelength and interface does the LRF0405C use?
Wavelength: 1535 +/- 5 nm. Interface: UART, 3.3 V TTL level.
How accurate is the LRF0405C?
Published ranging accuracy: +/-2 m. Update rate: Single measurement or 1 to 10 Hz.
How much does the LRF0405C cost?
From $400 per unit, shipping included, at 500+ pieces. Smaller quantities use the higher tiers in the volume table (single-piece tier: $650).
What laser safety class is stated for the LRF0405C?
Class I stated in the module document. Final accessible-emission classification applies to the complete configuration.
Published range
4,000 m or more at 30% reflectance and visibility of at least 6 km2.3 m x 2.3 m target range
Interface
UART, 3.3 V TTL level
Wavelength
1535 +/- 5 nm
Weight
≤32 ±1 g

The details

LRF0405C specifications

Read every value with its conditions. View the model documents for integration.

Additional specifications

LRF0405C Additional specifications
ParameterSpecification & conditions
ModelLRF0405C
Specified minimum range15 m or less
2.3 m x 2.3 m target range4,000 m or more at 30% reflectance and visibility of at least 6 km2.3 m x 2.3 m target range
0.5 m x 1.7 m human-size target range1,200 m or more at 30% reflectance and visibility of at least 6 km
Ranging frequencySingle measurement or 1 to 10 Hz
Multi-target reportingUp to 3 targets
Ranging accuracy+/-2 m
Reported range resolution0.1 m or better
Valid measurement rate98% or higher under specified test conditions
False-alarm rate1% or lower under specified test conditions
Laser wavelength1535 +/- 5 nm
Module laser-safety statementClass I stated in the module document. Final accessible-emission classification applies to the complete configuration.
Pulse energy200 microjoules or more
Beam divergence0.6 mrad or less
Transmitter lens diameter8 mm
Receiver lens diameter16 mm
Connector modelFWF08002-S06B13W5M
Communication interfaceUART, 3.3 V TTL level
Supply voltage3 to 5 V DC (the datasheet pin table also lists 4.5–16 V; check before wiring)
Power-control inputPOWER_ON; module on above 2.7 V and off below 0.3 V, as stated in the current interface table
Standby power1 mW or less
Average power2.5 W or less at 10 Hz
Peak power7 W or less; the current source references 12 V
Pin 1Positive power supply; red conductor
Pin 2Power ground; black conductor
Pin 3POWER_ON control; white conductor
Pin 4UART_TX, 3.3 V TTL; yellow conductor
Pin 5UART_RX, 3.3 V TTL; green conductor
Dimensions (L x W x H)48 × 30.5 × 21 mm
Weight≤32 ±1 g
Operating temperature-40 to +70 degrees C
Storage temperature-55 to +75 degrees C
Impact resistanceTested to the factory environmental shock test procedure (details on request)
Vibration resistanceTested to the factory environmental vibration test procedure (details on request)

Documents

Document notes & versions
ENGINEERING FILES

Technical Downloads

Use the current document revision for design review and confirm the ordered connector and mechanical configuration before release.

Product overview

LRF0405C 1535 nm Laser Rangefinder Module

LRF0405C is a laser rangefinder module for OEM integration, with a published test range of 4 km and a UART interface. Confirm target conditions, configuration and the current datasheet before integration.

LRF0405C is a 48 × 30.5 × 21 mm, ≤32 g 1535 nm rangefinder with a 200 µJ ER200 source, for observation and survey devices that need ≥4,000 m on a reference panel in a compact box.

WhatsApp about LRF0405C
From $400 USD / unitLowest published unit price at 500+ pieces. Shipping included.
B2B PURCHASING

Volume Pricing

Published unit prices apply only to the stated quantity band. Configuration, qualification, tax and Incoterm details are confirmed in the quotation.

USD / unit
1–19 piecesBase tier$650 USDPublished unit price
20–100 pieces$600 USDSave 8%
101–299 pieces$500 USDSave 23%
300–499 pieces$450 USDSave 31%
500+ piecesLowest unit price$400 USDLowest published price · Save 38%
Commercial terms and lead time are confirmed in the quotation.

Integration library

Go into the details.

Drawings, test conditions and application notes. Open the part you need.

Selection
SELECTION

Choosing LRF0405C against nearby models

Test cases: ≥4,000 m on a 2.3 × 2.3 m target and ≥1,200 m on a 0.5 × 1.7 m object at 30% reflectance and ≥6 km visibility; accuracy ±2 m, minimum range ≤15 m.

LRF0310C uses the same envelope with ±1 m accuracy and less reach. For ≥6000 m on the reference target, step to LRF0610C or LRF0612C.

Published unit prices start at $400 at 500+ pieces; see Volume Pricing for all quantity bands.

Technical documentation & drawings
SPECIFICATIONS

LRF0405C datasheet values

Figures are reproduced from the LRF0405C datasheet. Read each value together with the test condition printed beside it.

Specifications

LRF0405C is a 1535 nm pulsed distance-measurement module. Its assigned laser source is ER200; receiver-component data below come from the supplied APD-A13B001 R01 document. The three specification levels describe different assemblies and measurement conditions.

1. LRF0405C module specifications

LRF0405C — Basic Ranging Performance
Model LRF0405C
Specified minimum range 15 m or less
2.3 m x 2.3 m target range 4,000 m or more at 30% reflectance and visibility of at least 6 km
0.5 m x 1.7 m human-size target range 1,200 m or more at 30% reflectance and visibility of at least 6 km
Ranging frequency Single measurement or 1 to 10 Hz
Multi-target reporting Up to 3 targets
Ranging accuracy +/-2 m
Reported range resolution 0.1 m or better
Valid measurement rate 98% or higher under specified test conditions
False-alarm rate 1% or lower under specified test conditions
LRF0405C — Optical Parameters
Laser wavelength 1535 +/- 5 nm
Module laser-safety statementClass I stated in the module document. Final accessible-emission classification applies to the complete configuration.
Pulse energy 200 microjoules or more
Beam divergence 0.6 mrad or less
Transmitter lens diameter 8 mm
Receiver lens diameter 16 mm
LRF0405C — Electrical and Communication Interface
Connector model FWF08002-S06B13W5M
Communication interface UART, 3.3 V TTL level
Supply voltage 3 to 5 V DC (the datasheet pin table also lists 4.5–16 V; check before wiring)
Power-control input POWER_ON; module on above 2.7 V and off below 0.3 V, as stated in the current interface table
Standby power 1 mW or less
Average power 2.5 W or less at 10 Hz
Peak power 7 W or less; the current source references 12 V
LRF0405C — Five-Pin Interface
Pin 1 Positive power supply; red conductor
Pin 2 Power ground; black conductor
Pin 3 POWER_ON control; white conductor
Pin 4 UART_TX, 3.3 V TTL; yellow conductor
Pin 5 UART_RX, 3.3 V TTL; green conductor
LRF0405C — Mechanical and Environmental
Dimensions (L x W x H) 48 x 30.5 x 21 mm
Weight≤32 ±1 g
Operating temperature -40 to +70 degrees C
Storage temperature -55 to +75 degrees C
Impact resistance Tested to the factory environmental shock test procedure (details on request)
Vibration resistance Tested to the factory environmental vibration test procedure (details on request)

Model-specific mechanical and interface drawings

LRF0405C Mechanical and Environmental source drawing 1
LRF0405C: Mechanical and Environmental.
LRF0405C UART electrical interface drawing; verify pin assignments against the current datasheet
LRF0405C: Mechanical and Environmental.

2. ER200 source-laser specifications

ER200 standalone laser component
ParameterValue
Optical wavelength1535 nm
Pulse energy200 µJ (source value; no minimum/maximum qualifier)
Optical pulse width5 ns (FWHM)
Drive pulse width<2.4 ms
Repetition rate10 Hz (source operating point, not a stated range)
Pulse-energy stability10% (definition/statistical method not stated)
Raw beam diameter0.3 mm
Initial beam divergence8 mrad (source value; no ≤ qualifier)
Transverse modeTEM00
Operating / storage temperature−40 to +65 °C / −55 to +85 °C
Package dimensions / mass21 × 8 × 6.8 mm / 7 g
Component electrical entry2 V, 10 A
Shock / vibration entries1500 G, 0.5 ms / 20–2000 Hz, 20 G
Stated service life>1 million shots; test conditions not supplied

The electrical entries describe the component drive, not the module supply input. Drive conditions and pulse-width definitions must follow the component document and the individual factory record. An optical pulse-width value is not a pump-drive duration.

3. APD-A13B001 receiver-component specifications

Small screens: swipe the table horizontally to read all measurement conditions.

Supplied APD200 document — component values and conditions
ParameterValueMeasurement condition / scope
Device / active diameterAPD-A13B001 R01 / 200 µmSupplied APD200 document, p1
Detector spectral response interval800–1700 nmDetector response; not the filter passband
Responsivity0.9 A/W minimum; 1.0 A/W typicalλ = 1550 nm; incident power = 1 µW; M = 1
Dark current8 nA typical; 50 nA maximumVR = VBR − 3 V; incident power = 0
Multiplication factorM ≥10 / M ≥30λ = 1550 nm; 1 µW; respectively VBR − 3 V / VBR − 1 V
−3 dB bandwidth0.6 GHz minimum; 1.25 GHz typicalM = 10; RL = 50 Ω
Breakdown voltage35–50 VReverse current = 10 µA; incident power = 0
Capacitance1.8 pF typical; 2.0 pF maximumVR = VBR − 3 V; f = 1 MHz
Breakdown temperature coefficient0.05 minimum / 0.11 typical / 0.15 maximum V/°CReverse current = 10 µA; dark; −55 to +85 °C
Operating / storage temperature−40 to +85 °C / −55 to +125 °CComponent absolute-maximum table; not module environmental ratings
Maximum biasVBRAbsolute maximum, not a recommended operating setpoint
Maximum forward / reverse current5 mA / 3 mAAbsolute maximum ratings, not continuous design targets
Filter centre wavelength1535 ±5 nmSupplied filter table, p3
Filter FWHM<37 nmFull width at half maximum
Transmission at centre wavelength>90%Filter specification, not total receiver throughput
Blocking specificationT <1%; source lists 400–1750 nmStop-band/transition edges are not numerically defined; the stated blocking span is not a guarantee at every wavelength.
Optical surface quality60/40Source label: surface quality; not a transmission value

Responsivity is measured at 1550 nm; a value measured there is not silently relabeled as a measured 1535 nm value. Absolute maxima are stress limits. The filter document includes an illustrative spectrum, but does not define numerical transition edges or off-axis performance. No additional spectral guarantee is inferred.

Integration checklist
INTEGRATION

Integrating LRF0405C into your design

  • Supply: 3 to 5 V DC; the datasheet pin table also lists 4.5–16 V, so check the value for your batch before you design the rail.
  • Power: standby ≤1 mW, average ≤2.5 W at 10 Hz, peak ≤7 W.
  • Connector FWF08002-S06B13W5M: pin 1 supply (red), pin 2 ground (black), pin 3 POWER_ON (white; on above 2.7 V, off below 0.3 V), pin 4 UART_TX and pin 5 UART_RX at 3.3 V TTL.
  • Optics: Φ8 mm transmit, Φ16 mm receive, ≤0.6 mrad divergence.
Applications
APPLICATIONS

Where LRF0405C is used

  • Digital observation devices. Adding distance to compact thermal or day cameras.
  • Survey and forestry. Ranging to trees, slopes and structures over several kilometres.
  • UAV gimbals. Compact long-range module for inspection payloads.
Questions & answers
FAQ

LRF0405C integration questions

Which supply voltage should I design for?

The current documents give two entries (3–5 V and 4.5–16 V). Ask us to confirm for your batch; do not assume both.

How do I turn it on from my MCU?

Drive POWER_ON above 2.7 V to enable and below 0.3 V to disable.

What is the human-size target range?

≥1,200 m on a 0.5 × 1.7 m object at 30% reflectance and ≥6 km visibility.

HARDWARE

LRF0405C mounting, wiring and commands

Taken from the LRF0405C outline drawing and user manual. Check hole positions against the drawing or the STEP file before machining a bracket.

Mounting

Three M2.5 threaded mounting holes, 4.5 mm deep; the two holes shown on the side view are 26.5 mm apart. The position of the third hole is not dimensioned on the drawing.

Request the LRF0405C STEP model for your bracket design.

Serial settings

Logic level
3.3 V TTL
Default baud rate
115200 bit/s
Frame format
8N1
Checksum
Low 8 bits of the sum of the device code, command code and parameter bytes (header and length byte excluded).

Common commands

CommandSend (hex)Reply (hex)Notes
Single measurementEE 16 02 03 02 05—Reply: EE 16 06 03 02 STATUS INT_H INT_L DEC CS. Distance (m) = INT_H x 256 + INT_L + DEC x 0.1. STATUS 0x04 = out of range.
Continuous measurementEE 16 02 03 04 07—Reply (repeated): EE 16 06 03 04 STATUS INT_H INT_L DEC CS. Distance (m) = INT_H x 256 + INT_L + DEC x 0.1. STATUS 0x04 = out of range.
Stop measurementEE 16 02 03 05 08EE 16 02 03 05 08Reply echoes the command.
Self-testEE 16 02 03 01 04—Reply: EE 16 06 03 01 S3 S2 S1 S0 CS (status bytes).
Set continuous rate to 1 HzEE 16 04 03 A1 01 00 A5EE 16 02 03 A1 A4Rate byte 0x01 to 0x0A; 0x05 = 5 Hz.
Read serial numberEE 16 02 03 A9 AC—Reply: EE 16 05 03 A9 MONYEAR NUM_H NUM_L CS.

Frames follow the LRF0405C user manual; every full frame has been checked against the manual's checksum rule. Open-source drivers: Drivers & wiring.

Engineering Q&A

Questions about LRF0405C

Wiring, protocol or integration question? Ask in the ERDI engineering community.

Ask an engineer about LRF0405C

LRF0405C quick answers

What are the LRF0405C dimensions?
48 × 30.5 × 21 mm.
How much does the LRF0405C weigh?
≤32 ±1 g.
What power does the LRF0405C need?
Supply: 3 to 5 V DC (the datasheet pin table also lists 4.5–16 V; check before wiring).
Which interface does the LRF0405C use?
UART, 3.3 V TTL level.
How much does one LRF0405C cost?
$650 for 1 piece, shipping included. Volume price from $400 at 500+ pieces.
What is the minimum order for the LRF0405C?
1 piece. Pay online by card or PayPal, or by bank transfer; shipping is free worldwide.
What is the LRF0405C lead time?
Standard warranty: one year. The lead time is stated on your proforma invoice (PI) before you pay.

Laser safety & status

Laser class
Class 1 (IEC 60825-1)
Status
Available to order

Laser class as stated in the module document. Classification of your finished product depends on its optical path and configuration.

ERDI TECH

Manufacturer · Chengdu · Founded 2021

Evidence-backed certifications: ISO 9001 · CE EMC

Technical inquiry

Discuss LRF0405C for your application.

Share the target, range, interface and expected quantity. Your selected model stays attached to the inquiry.

Request a review or quotation

Start with your work email and one line about the module or application. Add technical details if you have them.

No models attached.Name the models you are comparing in the requirement, or send the requirement without one.
Send me
Add technical requirements (optional)
Add project & contact details (optional)
Preparing the form. You can also send your request by email.

We reply within one business day (Chengdu, UTC+8).