Introducing Our Short-Range DToF Sensor Line

Short-range DToF selection starts with target reflectivity, minimum and maximum distance, output rate and the host supply. ERDI’s VB and H model records provide board-level and industrial integration options. Confirm an operating envelope against the exact model’s linked specification before committing to a design.

Two formats, one measurement principle

Compare the mounting format and host requirements for the specific model. A family label does not establish a shared supply, interface, update rate or safety classification.

  • VB — board-level integration. Check the selected model’s supply range, peak and average current, connector, board space and optical clearance.
  • H — industrial integration. Check the selected model’s input supply, mounting drawing, connector and environmental requirements before selecting a host enclosure.

Check minimum distance and target conditions

Check the blind zone and measurement range for the selected model and target reflectivity. A close target also needs sufficient illuminated area, a suitable incidence angle and an unobstructed optical path. Validate the intended target and lighting conditions at both the near and far limits of the application.

Choose the interface and output rate by model

The linked LRF22VB Specification V3.0 lists UART/IIC and 200 Hz, with 100, 50, 20, 10 and 1 Hz alternatives. The linked LRF50H Specification V3.0 lists UART and a 1 kHz default. Confirm the delivered hardware, firmware and settings before selecting an interface or output rate. These examples do not establish the same options for every VB or H model.

Where each model fits

Start with the measurement task: obstacle clearance, height sensing, position monitoring or another distance requirement. Match the target, minimum and maximum distance, required output rate, mounting envelope, input supply and operating environment to the exact model. Confirm performance in the intended setup before using the output in a control or protective function.

Power budget: board-level vs. cabinet-level

Size the supply for the exact model and operating mode. The linked LRF22VB Specification V3.0 lists a 3.0–3.6 V DC input, 40 mA average and 70 mA peak at 3.3 V, and average power below 0.2 W. The linked LRF50H Specification V3.0 lists 9–36 V DC, 34 mA average and 100 mA peak at 24 V, and average power of 0.8 W. These current rows are labelled average and peak, not guaranteed maximum limits, and do not give a complete test matrix for frequency, target and temperature. Confirm the delivered configuration and required supply margin; do not apply one VB or H example to the whole series.

Use the exact document and configuration

Use the selected model’s specification revision and delivered configuration as the basis for integration. Check supply limits, current definitions, distance units, pin assignments and available settings together. Resolve any conflicting document, label or configuration information before treating a figure as a design requirement.

Specification references

The examples above use LRF22VB Specification V3.0, pages 2–4 and LRF50H Specification V3.0, pages 2–4, reviewed on 2026-10-13 UTC. Use the specification and settings for the delivered model when planning a supply or parser.

Getting started

Use our UART-TTL integration guide as an integration checklist, then implement the chosen model’s documented frame layout, distance unit, out-of-range value and checksum. For example, the linked V3.0 documents describe LRF22VB distance output in millimetres and LRF50H output in centimetres; a similar frame header does not make their parsers interchangeable. Send your mounting envelope, supply rail, target reflectivity, required range and update rate to tommy@erdimail.com or use the ERDILRF inquiry page to request a model and configuration check.