A rangefinder datasheet lists range at 90% reflectivity and at 10% reflectivity: the 90% figure describes a bright cooperative target, the 10% figure describes a dark grey surface in daylight. For the six ERDI H-series modules, the published ratio of the 10% range to the 90% range runs from 0.20 to 0.35, meaning a module that reaches 1,500 m on a bright surface may reach only 300 m on a dark one.
What “50 m at 90%” actually promises
The 90% figure in a rangefinder module datasheet is the range a module reaches under its stated test conditions: a highly reflective target, defined ambient light, and a clean optical path. It describes the datasheet’s best case, not an operating floor.
The 10% figure is a separate specification, measured at the same ambient conditions but against a target that returns far less light. The two figures describe the module at two calibration points only. Neither row covers targets outside those points, and no linear interpolation between them is published. A target at 10% reflectivity sits at the lower published boundary; a target darker than 10% is outside the datasheet’s stated scope entirely.
The H series spans 50 m to 1,500 m at 90% reflectivity. For each model, a matching 10% range is also published. Those two pairs per model are the only reflectivity-to-range data points in the product specifications.
Six rows, two columns, one computed ratio
The table below lists the two published range figures for each H-series module and adds a ratio column. The ratio is arithmetic — 10% range divided by 90% range — computed from the published datasheet rows. It is not a published specification.
| Model | 90% range (m) | 10% range (m) | Ratio (computed) | Rate note |
|---|---|---|---|---|
| LRF50H | 50 | 15 | 0.30 | 20 Hz–10 kHz, 1 kHz default |
| LRF100H | 100 | 30 | 0.30 | 20 Hz–10 kHz, 1 kHz default |
| LRF200H | 200 | 70 | 0.35 | 20 Hz–10 kHz, 1 kHz default |
| LRF300H | 300 | 100 | 0.33 | 1 kHz or 50 Hz — switches automatically to match echo strength |
| LRF600H | 600 | 200 | 0.33 | 1 kHz or 50 Hz — switches automatically to match echo strength |
| LRF1500H | 1,500 | 300 | 0.20 | 1 kHz or 50 Hz — switches automatically to match echo strength |
Range figures come directly from the published product records for each model. See Rangefinder Module Datasheet: What to Check for a guide to interpreting these columns.
Why one ratio cannot be borrowed across models
The ratio spans from 0.20 on the LRF1500H to 0.35 on the LRF200H. An engineer who assumes 0.33 and applies it to the LRF1500H would estimate 495 m on a 10% target instead of the published 300 m — a 65% overestimate. The signal budget that determines this ratio depends on the receiver aperture, the pulse energy, and the detection threshold of each design. Those values are specific to each module; they do not scale uniformly across the product family.
Identical 90% range figures also do not imply equal 10% performance. The LRF100H and LRF200H have the same accuracy spec and the same operating temperature range, yet their published 10% ranges differ (30 m vs 70 m), producing ratios of 0.30 and 0.35 respectively. The design differences between these two models are not stated in the published specifications; the ratio column is the only way to see this discrepancy in a table.
What the table does not say
The 10% figure is a calibration point. A target that reflects at 7% is below the lower published condition, and no datasheet row covers it. The module may still return a valid reading at reduced range, but how far reduced is not stated in the specifications.
The table also does not confirm that the 10% range holds at the same update rate as the 90% range. For the LRF300H, LRF600H, and LRF1500H, the update rate is 1 kHz or 50 Hz, switching automatically to match echo strength. A darker target returns a weaker echo; this may cause the module to hold the lower 50 Hz rate. No transition threshold is published — it is not possible to infer from the datasheet at which target reflectivity or distance the rate change occurs. For a broader discussion of how rangefinder accuracy specifications work, see the linked guide.
For the LRF50H, LRF100H, and LRF200H, rate is user-selectable from 20 Hz to 10 kHz with a 1 kHz default; these models do not describe automatic rate reduction based on echo strength in their published specifications.
Finally, beam divergence and spot size at the target also affect the effective return signal. A beam that overfills a small target loses reflected energy in proportion to the fill fraction — an effect independent of the surface reflectivity row in the datasheet.
Bracket your own target: a five-step checklist
Before treating either datasheet row as a confirmed operating point for a specific installation:
- Identify the actual surface. Name the material and record any available reflectivity measurement. Do not assign a reflectivity percentage by appearance alone. If the value is unknown, test with a known reference surface before accepting the datasheet row as the operating condition.
- Compare against both published points. If the target reflectivity falls between 10% and 90%, the useful range falls somewhere between the two rows. Neither boundary establishes the midpoint by itself; the datasheet does not publish the intermediate behaviour.
- Record the ambient light and optical path. Both range rows are measured under defined conditions; a dirty window, a direct sun angle, or additional optical elements in the beam path change the effective signal budget.
- Check the rate requirement separately. For models with adaptive frequency, verify whether the required update rate is consistent with the signal conditions at the intended distance and target. This cannot be inferred from the range row alone.
- Ask the supplier before the design is committed. The datasheet covers two reflectivity points. For targets outside those points, or for simultaneous range and rate requirements, confirming with engineering avoids a late-stage redesign. Send the target description and operating conditions to ERDI.
A two-board bench check
A bench measurement using two boards — one at approximately 90% reflectivity (matte white paper) and one at approximately 10% (flat black card) — gives a first-pass check of the datasheet ratio in a specific installation.
Place each board at a known distance inside the module’s published 10% range. Record the number of valid readings per second and the distance values for both boards at that distance. If the module reports valid readings on both boards within the datasheet’s accuracy row, the installation’s signal budget is consistent with both published points at that distance.
If the module reports invalid readings on the dark board at a distance where the datasheet implies valid readings, the ambient light, the optical path, or the target size may be reducing the effective return below the datasheet’s test condition. Document both the distance and the conditions before concluding that a module falls short. See Understanding Rangefinder Accuracy Specs for guidance on recording acceptance results.
FAQ
Is the 10% range a guarantee for dark objects?
No. The 10% range is a specification for a surface that reflects 10% of the incident light under the datasheet’s stated test conditions. A surface that reflects less than 10%, is wet, tilted, small relative to the beam spot, or at a higher ambient light level than the test, may return less signal than the 10% condition. The datasheet does not cover these cases, and the module may produce valid readings at a shorter range, or no valid readings at all. The 10% figure is the lower published boundary, not a guarantee for all dark surfaces.
Can I scale the 90% range by a fixed ratio to estimate the 10% range?
Not across models. The computed ratio of the 10% range to the 90% range runs from 0.20 to 0.35 across the six H-series modules listed in this article. Applying the LRF200H ratio of 0.35 to the LRF1500H would produce an estimate of 525 m instead of the published 300 m. Within a single model the ratio is a fixed arithmetic fact derived from the two published rows; across models it varies because the signal budget of each design is different. Use the published 10% figure for each model individually.
Does a weaker target change the update rate?
For the LRF300H, LRF600H, and LRF1500H, the published update rate is 1 kHz or 50 Hz, switching automatically to match echo strength. A darker target returns a weaker echo, which may cause the module to hold the lower 50 Hz rate. The transition threshold is not published. For the LRF50H, LRF100H, and LRF200H, rate is user-selectable from 20 Hz to 10 kHz; these models do not describe automatic rate reduction based on echo strength in their published specifications.
Category pages: Laser rangefinder module
Models mentioned in this article
- LRF200H905 nm · up to 200 m · UART · I2C · 20 ± 2 g1 pc $250 · shipping includedSee price & buy
- LRF1500H905 nm · up to 1.5 km · UART · I2C · 20 ± 2 g1 pc $400 · shipping includedSee price & buy
- LRF100H905 nm · up to 100 m · UART · I2C · 20 ± 2 g1 pc $200 · shipping includedSee price & buy
- LRF50H905 nm · up to 50 m · UART · 15 ± 2 g1 pc $100 · shipping includedSee price & buy