A laser rangefinder accuracy of ±1 m means a single reading can sit up to 1 m either side of the true distance under the stated test conditions; many modules add a distance-proportional term beyond a break point. Worked example from the catalog: the LR1000E2 states ±1 m (D ≤ 400 m) and ±(1 + 0.001D) m beyond. At 300 m the window is 299–301 m; at 1,000 m it is ±(1 + 1) = ±2 m, so 998–1,002 m.
| True distance | LR1000E2 stated accuracy | Reading window |
|---|---|---|
| 100 m | ±1 m | 99–101 m |
| 400 m | ±1 m | 399–401 m |
| 700 m | ±1.7 m | 698.3–701.7 m |
| 1,000 m | ±2 m | 998–1,002 m |
Error sources beyond the spec line: target tilt and a large spot falling on an edge add error the datasheet does not include, and averaging N readings reduces random noise (roughly by √N) but not a fixed offset. See beam divergence and spot size.
Accuracy specifications can use an absolute error, a percentage of distance, or a formula that combines both. Read the exact distance band and units for the model you are ordering. The two examples below come from the public LRF3000A1 and LR2000E2 user manuals marked v1.2 | 2025.10, checked on 14 October 2026. Confirm the applicable controlled revision and supplied configuration before design release.
Read the formula for the stated distance band
| Model and source | Published accuracy | How to apply it |
|---|---|---|
| LRF3000A1, user manual p.2 | d ≤ 100 m: ±0.7 m; d > 100 m: ±(0.7 + 0.003d) m |
The accuracy row specifies a building target. The far-distance expression includes both terms; d is in meters. |
| LR2000E2, user manual p.2 | d ≤ 400 m: ±1 m; 400 m < d ≤ 2000 m: ±0.004d |
The listed measurement range is 4–2000 m. The far-distance expression is 0.4% of d; do not add the near-band 1 m to it. The accuracy table does not specify target reflectivity or size. |
A piecewise specification tells you which expression to use. It does not establish that every rangefinder has the same error model, or that the terms identify only two physical causes. Keep the inequality signs: 100 m belongs to the LRF3000A1 near band, and 400 m belongs to the LR2000E2 near band.
What it means at your operating distance
At 3000 m, the LRF3000A1 building-target formula gives ±(0.7 + 0.003 × 3000) m = ±9.7 m. Its manual lists a maximum-ranging-distance specification of ≥3000 m on a 70%-reflectivity building target in clear weather with visibility ≥4 km. Use 3000 m here as a calculation point under that reference, rather than a hard maximum for every target.
For LR2000E2 at 2000 m, the published far-band expression gives ±(0.004 × 2000) m = ±8 m. At 400 m, use the separate ±1 m band. Do not extend a formula beyond the documented range or assume an unstated transition between bands. These calculations translate the manual statements; they are not measured performance results for your installation.
Accuracy, resolution and repeatability answer different questions
- Accuracy: the published distance-error specification, with its distance band and any stated target, environment or statistical qualifier.
- Resolution: the reported distance increment. A fine output increment does not establish equally fine accuracy.
- Repeatability: the spread of repeated measurements under the stated test conditions. Read it separately from resolution and accuracy; do not infer it from the number of displayed digits.
Read valid-measurement and false-alarm rates by model
The same accuracy table may give a different valid-measurement rate for different distances. LR2000E2 p.2 lists ≥98% for d ≤ 400 m and ≥80% for 400 m < d ≤ 2000 m. LRF3000A1 p.2 lists ≥98% without a separate distance band on that row. Both reviewed manuals list a false-alarm rate of ≤1%. These are statements from those two manuals, not a specification for every ERDI module.
The reviewed rate rows do not define the counting denominator, sample size, validity test or false-alarm test procedure. Ask for those definitions and the applicable test conditions before comparing percentages or predicting missed readings. Do not treat a manual threshold as an observed failure rate in your application.
Check conditions and motion requirements before selecting
Conditions must come from the relevant row or note. LRF3000A1 explicitly identifies a building target for accuracy and a 70%-reflectivity building target, clear weather and visibility ≥4 km for its long-range specification. LR2000E2 does not identify reflectivity or target size in its accuracy table. Do not transfer the conditions from one model or one specification to another.
If your sensor or target moves, request the applicable static or dynamic error definition, motion conditions, measurement timing and configuration. Do not substitute an unverified related-model figure for the ordered module. Validate the selected configuration at your working distances, on your actual targets and in the expected environment.
The practical rule
Start with the exact model, document revision and working-distance band. Calculate the published expression at your required distances, then check reporting resolution, repeatability, rate definitions and test conditions separately. ERDI TECH LTD can help review the applicable documentation: browse the module catalog, send your application requirements, or email tommy@erdimail.com. Include target material and size, minimum and maximum distance, motion, environment, required error and interface.
Accuracy specification FAQ
Should I add the near-range error to a percentage error?
Only when the applicable formula includes both terms. LRF3000A1 uses ±(0.7 + 0.003d) m above 100 m. LR2000E2 uses ±0.004d for 400 m < d ≤ 2000 m, without adding the near-band 1 m.
What does the LR2000E2 formula give at 2000 m?
Its public v1.2 manual specifies ±0.004d for 400 m < d ≤ 2000 m. With d in meters, the expression gives ±8 m at 2000 m. Target reflectivity and size are not specified in its accuracy table.
Does fine resolution guarantee the same accuracy?
No. Resolution is the reported distance increment. Accuracy and repeatability must be read separately, with their stated conditions.
Is the valid-measurement rate at least 98% for every model and distance?
No universal rate is established here. LR2000E2 p.2 lists ≥98% for d ≤ 400 m and ≥80% for 400 m < d ≤ 2000 m. Confirm the selected model, conditions and counting method.
What should I request before comparing false-alarm percentages?
Request the exact model and revision, false-alarm definition, counting denominator, sample size and test procedure. The two reviewed manuals list ≤1%, but their rate rows do not define that procedure.
Source manuals
- LRF3000A1 User Manual, v1.2 | 2025.10, pp.1–2; public edition labeled 2026-09-06 on the model page.
- LR2000E2 User Manual, v1.2 | 2025.10, pp.1–2; public edition labeled 2026-09-06 on the model page.
Frequently asked questions
How accurate is a laser range finder?
Accuracy is stated per model: in the ERDILRF catalog from ±5 cm (short-range VB sensors under 5 m) to ±2 m (long-range 1535 nm modules). Always read the distance range the figure applies to.
How accurate is a laser distance measurement?
For a time-of-flight sensor the limit is timing: 1 ns of error equals about 15 cm. Modules average many pulses internally, which is how short-range sensors reach centimetre accuracy.
Are cheap rangefinders any good?
Price follows range and pulse energy more than accuracy. A low-cost short-range sensor can be more accurate at 5 m than a long-range module; compare the stated accuracy at your distance, not the headline range.
Related technical guides
Category pages: 100 m laser distance sensor · Laser rangefinder module
Models mentioned in this article
- LR2000E2905 nm · up to 2 km · UART · TTL1 pc $120 · shipping includedSee price & buy
- LRF3000A1905 nm · up to 3 km · UART · TTL · 12 ± 0.5 g1 pc $200 · shipping includedSee price & buy
- LR1000E2905 nm · up to 1 km · UART · TTL · ≤10 g1 pc $80 · shipping includedSee price & buy